Normal/Reversed Phase Columns
P/N: 00111-21044
Xtimate PS/DVB, 5µm, 100Å, 4.6×300mm (1pcs/pk)
Xtimate PS/DVB column utilizes polystyrene-divinylbenzene (PS/DVB) matrix, offering exceptional mechanical strength with a porous structure. Unlike traditional silica-based reversed-phase columns, ...
P/N: 00111-21043
Xtimate PS/DVB, 5µm, 100Å, 4.6×250mm (1pcs/pk)
Xtimate PS/DVB column utilizes polystyrene-divinylbenzene (PS/DVB) matrix, offering exceptional mechanical strength with a porous structure. Unlike traditional silica-based reversed-phase columns, ...
P/N: 00111-21041
Xtimate PS/DVB, 5µm, 100Å, 4.6×150mm (1pcs/pk)
Xtimate PS/DVB column utilizes polystyrene-divinylbenzene (PS/DVB) matrix, offering exceptional mechanical strength with a porous structure. Unlike traditional silica-based reversed-phase columns, ...
P/N: 00111-21034
Xtimate PS/DVB, 5um, 100Å, 4.0×250mm (1pcs/pk)
Xtimate PS/DVB column utilizes polystyrene-divinylbenzene (PS/DVB) matrix, offering exceptional mechanical strength with a porous structure. Unlike traditional silica-based reversed-phase columns, ...
P/N: 00111-21032
Xtimate PS/DVB, 5um, 100Å, 4.0×150mm (1pcs/pk)
Xtimate PS/DVB column utilizes polystyrene-divinylbenzene (PS/DVB) matrix, offering exceptional mechanical strength with a porous structure. Unlike traditional silica-based reversed-phase columns, ...
P/N: 00121-21044
Xtimate Lactose-NH2, 5µm, 4.6×300mm (1pcs/pk)
Xtimate Lactose-NH2 column uses a special bonding process to make the retention of lactose on the stationary phase more stable, resulting in an extremely low RSD value for the lactose peak area. It...
P/N: 00105-21043
Xtimate CN, 5µm, 4.6×250mm (1pcs/pk)
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00105-21042
Xtimate CN, 5µm, 4.6×200mm (1pcs/pk)
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00105-21041
Xtimate CN, 5µm, 4.6×150mm (1pcs/pk)
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00105-21039
Xtimate CN, 5µm, 4.6×100mm (1pcs/pk)
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00105-21031
Xtimate CN, 5µm, 4.0×125mm (1pcs/pk)
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00105-11041
Xtimate CN, 3µm, 4.6×150mm (1pcs/pk)
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00105-11028
Xtimate CN, 3µm, 4.6×50mm (1pcs/pk)
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00107-31041
Xtimate C4, 10µm, 4.6×150mm (1pcs/pk)
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00107-21051
Xtimate C4, 5µm, 7.8×250mm (1pcs/pk)
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00107-21050
Xtimate C4, 5µm, 7.8×150mm (1pcs/pk)
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00107-21046
Xtimate C4, 5µm, 6.5×250mm (1pcs/pk)
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00107-21049
Xtimate C4, 5µm, 7.8×100mm (1pcs/pk)
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00107-21045
Xtimate C4, 5µm, 6.5×150mm (1pcs/pk)
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00107-21059
Xtimate C4, 5µm, 6.0×250mm (1pcs/pk)
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00107-21058
Xtimate C4, 5µm, 6.0×150mm (1pcs/pk)
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00107-21044
Xtimate C4, 5µm, 4.6×300mm (1pcs/pk)
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00107-21043
Xtimate C4, 5µm, 4.6×250mm (1pcs/pk)
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00107-21042
Xtimate C4, 5µm, 4.6×200mm (1pcs/pk)
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
Column Specifications
C18 Columns
| Series | Column | pH Range | Max Temperature | Max Pressure Tolerance |
| Ultisil Series | Ultisil LP-C18 | 0.5-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
| Ultisil LP-Aq | 1.0-8.0 | |||
| Ultisil XB-C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
| Ultisil AQ-C18 | 2.0-8.0 | |||
| Ultisil Plus C18 | 2.0-8.0 | |||
| Ultisil Alk C18 | 2.0-8.0 | |||
| Ultisil PAH | 2.0-8.0 | |||
| Ultisil Polar RP | 2.0-8.0 | |||
| Ultisil ODS-3 | 2.0-8.0 | |||
| Ultisil XS-C18 | 2.0-8.0 | |||
| Ultisil Plus LP-C18 | 0.5-8.0 | |||
| Xtimate Series | Xtimate C18 | 1.0-12.5 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
| Xtimate Polar RP | 1.0-12.5 | |||
| Blossmate Series | Blossmate C18 | 2.0-8.0 | 60 °C | 40 MPa |
| Blossmate Aqs C18 | 2.0-8.0 | |||
| Blossmate ST-C18 | 1.0-11.0 | |||
| Topsil Series | Topsil C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa |
| Welchrom Series | Welchrom C18 | 2.0-8.0 | 60 °C | 40 MPa |
| Welchrom Vantage C18 | 2.0-8.0 | 60 °C | 40 MPa | |
| Boltimate Series | Boltimate C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
60 MPa |
| Boltimate EXT-C18 | 1.5-12.0 | |||
| Boltimate LP-C18 | 1.0-8.0 |
C8, C4, C3, C1 and Phenyl Columns
| Series | Column | pH Range | Max Temperature | Max Pressure Tolerance |
| Ultisil Series | Ultisil XB-C8 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
| Ultisil LP-C8 | 1.0-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
| Ultisil F-C8 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
| Ultisil Plus-C8 | 2.0-8.0 | |||
| Ultisil XB-Phenyl | 2.0-8.0 | |||
| Ultisil Phenyl-Ether | 2.0-8.0 | |||
| Ultisil PFP | 2.0-8.0 | |||
| Ultisil Plus-phenyl | 2.0-8.0 | |||
| Ultisil XB-C4 | 2.0-8.0 | |||
| Ultisil LP-C3 | 1.0-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
| Ultisil XB-C30 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
| Ultisil XB-C1 | 2.0-8.0 | |||
| Ultisil XB-CN | 2.0-8.0 | |||
| Ultisil LP-CN | 1.0-8.0 | |||
| Xtimate Series | Xtimate C8 | 1.0-12.5 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
| Xtimate Phenyl-Hexyl | 1.0-12.5 | |||
| Xtimate C4 | 1.0-12.5 | |||
| Blossmate Series | Blossmate C4 | 2.0-8.0 | 60 °C | 40 MPa |
| Blossmate Phenyl | 2.0-8.0 | |||
| Topsil Series | Topsil C8 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa |
| Topsil phenyl-Hexyl | 2.0-8.0 | |||
| Topsil CN | 2.0-8.0 | |||
| Welchrom Series | Welchrom C8 | 2.0-8.0 | 60 °C | 40 MPa |
| Boltimate Series | Boltimate C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
60 MPa |
| Boltimate Phenyl-Hexyl | 2.0-8.0 | |||
| Boltimate EXT-C18 | 1.5-12 | |||
| Boltimate EXT-PFP | 1.5-10 | |||
| Boltimate HILIC | 2.0-8.0 | |||
| Boltimate LP-C18 | 1.0-8.0 | |||
| Boltimate C8 | 2.0-8.0 | |||
| Boltimate Phenyl | 2.0-8.0 |
Normal-Phase Columns
| Series | Column | pH Range | Max Temperature | Max Pressure Tolerance |
| Ultisil Series | Ultisil SiO2 | 2.0-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
| Ultisil Diol | 2.0-8.0 | |||
| Ultisil XB-NH2 | 2.0-8.0 | |||
| Ultisil XB-CN | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
| Topsil Series | Topsil Silica | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa |
| Topsil NH2 | 2.0-8.0 |
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device