Collection:
Column Protection For Prep LC Columns
104 products P/N: 00808-01116
Direct Connect Semi-prep guard column holder(10mm) (1pcs/pk)
Direct Connect Semi-prep guard column holder(10mm) for 10×10mm Semi-Prep Cartridge
The product includes:Direct Connect Semi-prep guard column holder(10mm) ×1
P/N: 00808-01106
Prep Guard column holder (21.2mm) (1pcs/pk)
Prep Guard column holder (21.2mm), for 21.2×10mm Semiprep Cartridge
The product includes:Prep Guard column holder (21.2mm) ×1
P/N: 00808-01117
Prep Guard column holder (30mm) (1pcs/pk)
Prep Guard column holder(30mm), for 30×10mm Prep Cartridge
P/N: 00808-01110
Preparative Guard Column Holder (50mm) (1pcs/pk)
Preparative Guard column holder (50mm), for 50×10mm Prep Cartridge
The product includes:Prep Guard Column Holder (50mm) ×1
P/N: 00808-01208
Preparative In-line Filter Kit, 21.2mm (1pcs/pk)
Preparative In-line Filter Kit, 21.2mm
The product includes:Preparative In-line Filter (21.2mm) ×12µm 21.2mm Frit (P/N : 00808-01209) ×1
P/N: 00808-01209
Replacement Frit, 21.2mm, 2µm (1pcs/pk)
21.2mm Frit, 2μm pore size for Preparative Precolumn Filter (P/N : 00808-01208)
The product includes:21.2mm Replacement Frit, 2μm ×1
P/N: H00808-04401
Ultisil XB-C18, Semi-Prep Cartridge: 5µm, 120Å, 10×10mm (1pcs/pk)
Welch preparative guard column cartridges use the same packing as the preparative column, which can intercept some of the same polar substances in the sample and prevent them from contaminating and...
P/N: H00808-24418
Ultisil XB-C18, Semi-Prep Cartridge: 5µm, 300Å, 10×10mm (1pcs/pk)
Welch preparative guard column cartridges use the same packing as the preparative column, which can intercept some of the same polar substances in the sample and prevent them from contaminating and...
P/N: H00808-14801
Ultisil XB-C18, Prep Cartridge: 5µm, 120Å, 21.2×10mm (1pcs/pk)
Welch preparative guard column cartridges use the same packing as the preparative column, which can intercept some of the same polar substances in the sample and prevent them from contaminating and...
P/N: H00808-14818
Ultisil XB-C18, Prep Cartridge: 5µm, 300Å, 21.2×10mm (1pcs/pk)
Welch preparative guard column cartridges use the same packing as the preparative column, which can intercept some of the same polar substances in the sample and prevent them from contaminating and...
P/N: H00808-05401
Ultisil XB-C18, Semi-Prep Cartridge: 10µm, 120Å, 10×10mm (1pcs/pk)
Welch preparative guard column cartridges use the same packing as the preparative column, which can intercept some of the same polar substances in the sample and prevent them from contaminating and...
P/N: H00808-15801
Ultisil XB-C18, Prep Cartridge: 10µm, 120Å, 21.2×10mm (1pcs/pk)
Welch preparative guard column cartridges use the same packing as the preparative column, which can intercept some of the same polar substances in the sample and prevent them from contaminating and...
P/N: H00808-08601
Ultisil XB-C18, Prep Cartridge: 5µm, 120Å, 30×10mm (1pcs/pk)
Welch preparative guard column cartridges use the same packing as the preparative column, which can intercept some of the same polar substances in the sample and prevent them from contaminating and...
P/N: H00808-08610
Ultisil XB-C18, Prep Cartridge: 5µm, 300Å, 30×10mm (1pcs/pk)
Welch preparative guard column cartridges use the same packing as the preparative column, which can intercept some of the same polar substances in the sample and prevent them from contaminating and...
P/N: H00808-04402
Ultisil XB-C8, Semi-Prep Cartridge: 5µm, 120Å, 10×10mm (1pcs/pk)
Welch preparative guard column cartridges use the same packing as the preparative column, which can intercept some of the same polar substances in the sample and prevent them from contaminating and...
P/N: H00808-04419
Ultisil XB-C8, Semi-Prep Cartridge: 5µm, 300Å, 10×10mm (1pcs/pk)
Welch preparative guard column cartridges use the same packing as the preparative column, which can intercept some of the same polar substances in the sample and prevent them from contaminating and...
P/N: H00808-14802
Ultisil XB-C8, Prep Cartridge: 5µm, 120Å, 21.2×10mm (1pcs/pk)
Welch preparative guard column cartridges use the same packing as the preparative column, which can intercept some of the same polar substances in the sample and prevent them from contaminating and...
P/N: H00808-25411
Ultisil XB-C8, Semi-Prep Cartridge: 10µm, 300Å, 10×10mm (1pcs/pk)
Welch preparative guard column cartridges use the same packing as the preparative column, which can intercept some of the same polar substances in the sample and prevent them from contaminating and...
P/N: H00808-05802
Ultisil XB-C8, Prep Cartridge: 10µm, 120Å, 21.2×10mm (1pcs/pk)
Welch preparative guard column cartridges use the same packing as the preparative column, which can intercept some of the same polar substances in the sample and prevent them from contaminating and...
P/N: H00808-15826
Ultisil XB-C8, Prep Cartridge: 10µm, 300Å, 21.2×10mm (1pcs/pk)
Welch preparative guard column cartridges use the same packing as the preparative column, which can intercept some of the same polar substances in the sample and prevent them from contaminating and...
P/N: H00808-08802
Ultisil XB-C8, Prep Cartridge: 10µm, 120Å, 30×10mm (1pcs/pk)
Welch preparative guard column cartridges use the same packing as the preparative column, which can intercept some of the same polar substances in the sample and prevent them from contaminating and...
P/N: H00808-15403
Ultisil AQ-C18, Semi-Prep Cartridge: 10µm, 120Å, 10×10mm (1pcs/pk)
Welch preparative guard column cartridges use the same packing as the preparative column, which can intercept some of the same polar substances in the sample and prevent them from contaminating and...
P/N: H00808-15803
Ultisil AQ-C18, Prep Cartridge 10µm, 120Å, 21.2×10mm (1pcs/pk)
Welch preparative guard column cartridges use the same packing as the preparative column, which can intercept some of the same polar substances in the sample and prevent them from contaminating and...
P/N: H00808-24403
Ultisil AQ-C18, Semi-Prep Cartridge: 5µm, 120Å, 10×10mm (1pcs/pk)
Welch preparative guard column cartridges use the same packing as the preparative column, which can intercept some of the same polar substances in the sample and prevent them from contaminating and...
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device