Normal/Reversed Phase Columns
P/N: 00111-21048
Xtimate PS/DVB, 5μm, 100Å, 7.8×50mm
Xtimate PS/DVB column utilizes polystyrene-divinylbenzene (PS/DVB) matrix, offering exceptional mechanical strength with a porous structure. Unlike traditional silica-based reversed-phase columns, ...
P/N: 00111-21051
Xtimate PS/DVB, 5μm, 100Å, 7.8×250mm
Xtimate PS/DVB column utilizes polystyrene-divinylbenzene (PS/DVB) matrix, offering exceptional mechanical strength with a porous structure. Unlike traditional silica-based reversed-phase columns, ...
P/N: 00111-21044
Xtimate PS/DVB, 5μm, 100Å, 4.6×300mm
Xtimate PS/DVB column utilizes polystyrene-divinylbenzene (PS/DVB) matrix, offering exceptional mechanical strength with a porous structure. Unlike traditional silica-based reversed-phase columns, ...
P/N: 00111-21043
Xtimate PS/DVB, 5μm, 100Å, 4.6×250mm
Xtimate PS/DVB column utilizes polystyrene-divinylbenzene (PS/DVB) matrix, offering exceptional mechanical strength with a porous structure. Unlike traditional silica-based reversed-phase columns, ...
P/N: 00111-21041
Xtimate PS/DVB, 5μm, 100Å, 4.6×150mm
Xtimate PS/DVB column utilizes polystyrene-divinylbenzene (PS/DVB) matrix, offering exceptional mechanical strength with a porous structure. Unlike traditional silica-based reversed-phase columns, ...
P/N: 00111-21034
Xtimate PS/DVB, 5um, 100Å, 4.0×250mm
Xtimate PS/DVB column utilizes polystyrene-divinylbenzene (PS/DVB) matrix, offering exceptional mechanical strength with a porous structure. Unlike traditional silica-based reversed-phase columns, ...
P/N: 00111-21032
Xtimate PS/DVB, 5um, 100Å, 4.0×150mm
Xtimate PS/DVB column utilizes polystyrene-divinylbenzene (PS/DVB) matrix, offering exceptional mechanical strength with a porous structure. Unlike traditional silica-based reversed-phase columns, ...
P/N: 00121-21044
Xtimate Lactose-NH2, 5μm, 4.6×300mm
Xtimate Lactose-NH2 column uses a special bonding process to make the retention of lactose on the stationary phase more stable, resulting in an extremely low RSD value for the lactose peak area. It...
P/N: 00103-21044
Xtimate NH2, 5μm, 4.6×300mm
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00103-21043
Xtimate NH2, 5μm, 4.6×250mm
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00103-21041
Xtimate NH2, 5μm, 4.6×150mm
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00105-21043
Xtimate CN, 5μm, 4.6×250mm
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00105-21042
Xtimate CN, 5μm, 4.6×200mm
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00105-21041
Xtimate CN, 5μm, 4.6×150mm
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00105-21039
Xtimate CN, 5μm, 4.6×100mm
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00105-21031
Xtimate CN, 5μm, 4.0×125mm
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00105-11041
Xtimate CN, 3μm, 4.6×150mm
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00105-11028
Xtimate CN, 3μm, 4.6×50mm
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00107-31041
Xtimate C4, 10μm, 4.6×150mm
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00107-21051
Xtimate C4, 5μm, 7.8×250mm
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00107-21050
Xtimate C4, 5μm, 7.8×150mm
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00107-21046
Xtimate C4, 5μm, 6.5×250mm
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00107-21049
Xtimate C4, 5μm, 7.8×100mm
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00107-21045
Xtimate C4, 5μm, 6.5×150mm
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
Column Specifications
C18 Columns
Series | Column | pH Range | Max Temperature | Max Pressure Tolerance |
Ultisil Series | Ultisil LP-C18 | 0.5-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
Ultisil LP-Aq | 1.0-8.0 | |||
Ultisil XB-C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
Ultisil AQ-C18 | 2.0-8.0 | |||
Ultisil Plus C18 | 2.0-8.0 | |||
Ultisil Alk C18 | 2.0-8.0 | |||
Ultisil PAH | 2.0-8.0 | |||
Ultisil Polar RP | 2.0-8.0 | |||
Ultisil ODS-3 | 2.0-8.0 | |||
Ultisil XS-C18 | 2.0-8.0 | |||
Ultisil Plus LP-C18 | 0.5-8.0 | |||
Xtimate Series | Xtimate C18 | 1.0-12.5 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
Xtimate Polar RP | 1.0-12.5 | |||
Blossmate Series | Blossmate C18 | 2.0-8.0 | 60 °C | 40 MPa |
Blossmate Aqs C18 | 2.0-8.0 | |||
Blossmate ST-C18 | 1.0-11.0 | |||
Topsil Series | Topsil C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa |
Welchrom Series | Welchrom C18 | 2.0-8.0 | 60 °C | 40 MPa |
Welchrom Vantage C18 | 2.0-8.0 | 60 °C | 40 MPa | |
Boltimate Series | Boltimate C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
60 MPa |
Boltimate EXT-C18 | 1.5-12.0 | |||
Boltimate LP-C18 | 1.0-8.0 |
C8, C4, C3, C1 and Phenyl Columns
Series | Column | pH Range | Max Temperature | Max Pressure Tolerance |
Ultisil Series | Ultisil XB-C8 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
Ultisil LP-C8 | 1.0-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
Ultisil F-C8 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
Ultisil Plus-C8 | 2.0-8.0 | |||
Ultisil XB-Phenyl | 2.0-8.0 | |||
Ultisil Phenyl-Ether | 2.0-8.0 | |||
Ultisil PFP | 2.0-8.0 | |||
Ultisil Plus-phenyl | 2.0-8.0 | |||
Ultisil XB-C4 | 2.0-8.0 | |||
Ultisil LP-C3 | 1.0-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
Ultisil XB-C30 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
Ultisil XB-C1 | 2.0-8.0 | |||
Ultisil XB-CN | 2.0-8.0 | |||
Ultisil LP-CN | 1.0-8.0 | |||
Xtimate Series | Xtimate C8 | 1.0-12.5 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
Xtimate Phenyl-Hexyl | 1.0-12.5 | |||
Xtimate C4 | 1.0-12.5 | |||
Blossmate Series | Blossmate C4 | 2.0-8.0 | 60 °C | 40 MPa |
Blossmate Phenyl | 2.0-8.0 | |||
Topsil Series | Topsil C8 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa |
Topsil phenyl-Hexyl | 2.0-8.0 | |||
Topsil CN | 2.0-8.0 | |||
Welchrom Series | Welchrom C8 | 2.0-8.0 | 60 °C | 40 MPa |
Boltimate Series | Boltimate C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
60 MPa |
Boltimate Phenyl-Hexyl | 2.0-8.0 | |||
Boltimate EXT-C18 | 1.5-12 | |||
Boltimate EXT-PFP | 1.5-10 | |||
Boltimate HILIC | 2.0-8.0 | |||
Boltimate LP-C18 | 1.0-8.0 | |||
Boltimate C8 | 2.0-8.0 | |||
Boltimate Phenyl | 2.0-8.0 |
Normal-Phase Columns
Series | Column | pH Range | Max Temperature | Max Pressure Tolerance |
Ultisil Series | Ultisil SiO2 | 2.0-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
Ultisil Diol | 2.0-8.0 | |||
Ultisil XB-NH2 | 2.0-8.0 | |||
Ultisil XB-CN | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
Topsil Series | Topsil Silica | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa |
Topsil NH2 | 2.0-8.0 |
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device