Welcome to our new website!

New Series Alert! Welchrom 96-Well Plates Make a Grand Entrance!

New Series Alert! Welchrom 96-Well Plates Make a Grand Entrance!

Welch Materials, prioritizing product stability, has developed a new series of products, Welchrom® 96-Well Plates, through over a year of technical research and process testing. This series of products is primarily designed for customers involved in the pre-treatment of biological samples, aiming to provide customers with comprehensive solutions and customized services, making the pre-treatment of biological samples simpler and more efficient.

Welchrom® 96-Well Plates are divided into two major series:

  1. Welchrom® 96-Well Plates – Solid Phase Extraction (SPE) Plates
    Adopting an integrated design, these plates are suitable for processing large-volume biological samples. They enable concentration after elution of large-volume samples, enhancing detection sensitivity. Each well is filled with 10mg to 60mg of sorbent material.

2. Welchrom® 96 Microporous Extraction Plate

Adopting an integrated design, this plate is suitable for extracting target compounds from small-volume biological samples. It requires only a small amount of elution solvent to elute the target substances, eliminating the need for concentration and reconstitution steps. Each well is filled with 2mg to 5mg of sorbent material.

Product Features:

  1. Low Sorbent Volume, High Throughput, Less Prone to Clogging:
    • Compared to traditional SPE columns, this product has the advantages of low sorbent volume, high throughput, and reduced susceptibility to clogging.
  2. Diverse Adsorbent Types, Varied Product Specifications:
    • The product offers a diversity of adsorbent types and specifications to meet various experimental needs.
  3. Excellent Reproducibility, Stability, and Reliability:
    • Demonstrates good reproducibility and stability, providing reliable results and reducing matrix effects in LC-MS/MS analysis.

Application Case:

Product: Welchrom® BRP 96-Well Plates, 5mg/1mL.

Project: Illustration using the example of determining the levels of Hydrocortisone, Testosterone, and Progesterone in serum.

1. Sample Preparation:

  • Sample:100μL serum sample + 100μL methanol-water (50/50) containing 1% formic acid.
  • Sample with Standard Addition:100μL serum sample + 100μL methanol-water (50/50) containing 1% formic acid + 10μL 1μg/mL mixed standard.
  • Blank:100μL water + 100μL methanol-water (50/50) containing 1% formic acid.
  • Blank with Standard Addition:100μL water + 100μL methanol-water (50/50) containing 1% formic acid + 10μL 1μg/mL mixed standard.

2. Column Pass-Through Steps:

  • 96 Microporous Extraction Plate: Welchrom® BRP 96-Well Plates, 5mg/1mL.
  • Activation:200μL methanol, 200μL water;
  • Sample Loading: Preprocess samples;
  • Washing: Wash with 400μL methanol-water solution (35/65);
  • Elution: With 200μL of 1% formic acid in methanol, collecting in a 96-well plate, followed by UHPLC-MS/MS detection.

3. Chromatographic Conditions

UPLC Conditions:

  • Column: Ultisil® XB-C18 (00201-21010), 3μm, 2.1×50mm.
  • Guard Column Core: Ultimate® XB-C18 (00808-23001), Core: 3µm, 120Å, 2.1×10mm.
  • Mobile Phase: A: 0.1% formic acid aqueous solution, B: 0.1% formic acid in acetonitrile (40/60).
  • Column Temperature: 30℃.
  • Flow Rate: 0.2mL/min.
  • Injection Volume: 2µL.

Mass Spectrometry Conditions:

  • Ion Source: Electrospray Ionization (ESI).
  • Scan Mode: Positive ion scan.
  • Detection Mode: Multiple Reaction Monitoring (MRM) mode.
  • Ion Spray Voltage: 5500V.
  • Ion Source Temperature: 500℃.

Gas Curtain Gas (CUR): 10 psi. Drying Gas (GS1): 55 psi. Auxiliary Gas (GS2): 50 psi.

For other mass spectrometry parameters, refer to Table 2.


Table 1: Multiple Reaction Monitoring (MRM) Parameters

Chromatogram and actual sample test results

Figure 1 Schematic diagram of steroid hormone standard solution 50ng/mL
Figure 2 The spectrum of each target substance in the mixed control solution 50ng/mL
Figure 3 Serum sample profile
Figure 4 Serum spiked spectrum (concentration 50ng/mL)

Table 2: Spike Recovery Rates

Compound Spiked Concentration (ng/mL) Average Recovery Rate (%) RSD (N≥50%)
Hydrocortisone 50ng/mL 100.80% 7.49%
Testosterone 50ng/mL 104.38% 9.63%
Progesterone 50ng/mL 90.63% 9.00%

Product information

Welchrom® 96-Well Solid Phase Extraction Plate

P/N Specification
01140-01608 Welchrom® BRP 96-well plates,
60mg/2mL,1pk
01140-01608 Welchrom® BRP 96-well plates,
50mg/2mL,1pk
01140-01308 Welchrom® BRP 96-well plates,
50mg/2mL,1pk
01140-01108 Welchrom® BRP 96-well plates,
10mg/2mL,1pk
01140-02608 Welchrom® P-SAX 96-well plates,
30mg/2mL,1pk
01140-02508 Welchrom® P-SAX 96-well plates,
10mg/2mL,1pk
01140-03308 Welchrom® P-SCX 96-well plates,
30mg/2mL,1pk
01140-03108 Welchrom® P-SCX 96-well plates,
10mg/2mL,1pk
01140-04108 Welchrom® P-WCX 96-well plates,
10mg/2mL,1pk
01140-04208 Welchrom® P-WCX 96-well plates,
20mg/2mL,1pk
01140-05308 Welchrom® P-WAX 96-well plates,
30mg/2mL,1pk
01140-05108 Welchrom® P-WAX 96-well plates,
10mg/2mL,1pk
01140-06508 Welchrom® C18E 96-well plates,
50mg/2mL,1pk
01140-06308 Welchrom® C18E 96-well plates,
30mg/2mL,1pk
01140-06258 Welchrom® C18E 96-well plates,
25mg/2mL,1pk
01140-06108 Welchrom® C18E 96-well plates,
10mg/2mL,1pk
01140-07608 Welchrom® PLR (phospholipid removal)
96-well plates, 60mg/2mL, 1pk
01140-07508 Welchrom® PLR (phospholipid removal)
96-well plates, 50mg/2mL, 1pk
01140-07308 Welchrom® PLR (phospholipid removal)
96-well plates, 30mg/2mL, 1pk

Welchrom® 96 Microwell Extraction Plate

P/N Specification
01140-01059 Welchrom® BRP 96-well plates,
2mg/1mL,1pk
01140-01029 Welchrom® BRP 96-well plates,
2mg/1mL,1pk
01140-02059 Welchrom® P-SAX 96-well plates,
5mg/1mL,1pk
01140-02029 Welchrom® P-SAX 96-well plates,
2mg/1mL,1pk2mg/1mL,1pk
01140-03059 Welchrom® P-SCX 96-well plates,
5mg/1mL,1pk
01140-03029 Welchrom® P-SCX 96-well plates,
2mg/1mL,1pk
01140-04059 Welchrom® P-WCX 96-well plates,
5mg/1mL,1pk
01140-04029 Welchrom® P-WCX 96-well plates,
2mg/1mL,1pk
01140-05059 Welchrom® P-WAX 96-well plates,
5mg/1mL,1pk
01140-05029 Welchrom® P-WAX 96-well plates,
2mg/1mL,1pk
01140-06059 Welchrom® C18E 96-well plates,
5mg/1mL,1pk
01140-06029 Welchrom® C18E 96-well plates,
2mg/1mL,1pk
01140-07059 Welchrom® PLR (phospholipid removal)
96-well plates, 5mg/1mL, 1pk
01140-07029 Welchrom® PLR (phospholipid removal)
96-well plates, 2mg/1mL, 1pk

Note: For other specifications, customization is available upon contact.

Storage Conditions and Shelf Life:Store at room temperature; under these conditions, the shelf life is 3 years.