P/N: H00204-31039
Ultisil XB-NH2, 5µm, 4.6×100mm (1pcs/pk)
Ultisil XB-NH2 column is typically used for the separation of various monosaccharides under reversed-phase conditions. However, it is not recommended for analyzing compounds containing aldehyde or ...
P/N: H00204-41041
Ultisil XB-NH2, 10µm, 4.6×150mm (1pcs/pk)
Ultisil XB-NH2 column is typically used for the separation of various monosaccharides under reversed-phase conditions. However, it is not recommended for analyzing compounds containing aldehyde or ...
P/N: H00204-41039
Ultisil XB-NH2, 10µm, 4.6×100mm (1pcs/pk)
Ultisil XB-NH2 column is typically used for the separation of various monosaccharides under reversed-phase conditions. However, it is not recommended for analyzing compounds containing aldehyde or ...
P/N: H00204-41043
Ultisil XB-NH2, 10µm, 4.6×250mm (1pcs/pk)
Ultisil XB-NH2 column is typically used for the separation of various monosaccharides under reversed-phase conditions. However, it is not recommended for analyzing compounds containing aldehyde or ...
P/N: H00204-21023
Ultisil XB-NH2, 3µm, 3.0×150mm (1pcs/pk)
Ultisil XB-NH2 column is typically used for the separation of various monosaccharides under reversed-phase conditions. However, it is not recommended for analyzing compounds containing aldehyde or ...
P/N: H00204-31025
Ultisil XB-NH2, 5µm, 3.0×250mm (1pcs/pk)
Ultisil XB-NH2 column is typically used for the separation of various monosaccharides under reversed-phase conditions. However, it is not recommended for analyzing compounds containing aldehyde or ...
P/N: H00204-31032
Ultisil XB-NH2, 5µm, 4.0×150mm (1pcs/pk)
Ultisil XB-NH2 column is typically used for the separation of various monosaccharides under reversed-phase conditions. However, it is not recommended for analyzing compounds containing aldehyde or ...
P/N: H02630-21107
Ultisil XB-NH2, 5µm, 30×150mm, 120Å (1pcs/pk)
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...
P/N: H02630-21108
Ultisil XB-NH2, 5µm, 30×250mm, 120Å (1pcs/pk)
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...
P/N: H02630-31108
Ultisil XB-NH2, 10µm, 30×250mm, 120Å (1pcs/pk)
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...