P/N: H00208-20038

Ultisil LP-C18, 3.5µm, 4.6×75mm (1pcs/pk)

Regular price $640.00 USD
Sale price $640.00 USD Regular price
Sale Sold out
Unit price
/per 
This is a pre order item. We will ship it when it comes in stock.

Ultisil LP-C18 column is a HPLC column designed to withstand 100% aqueous to 100% organic solvents. It features steric hindrance side-chain protection to shield hydroxyl groups and adopts a non-endcapped process. With strong spatial selectivity, it exhibits high orthogonality to conventional C18 columns, making it a suitable alternative for analytes that are difficult to separate on standard C18 columns. It demonstrates low stationary phase bleed under strongly acidic conditions, as an ideal baseline noise can be observed even when using an ELSD detector.

Quantity: 1 pcs/pk

Pairs well with


Ultisil Series HPLC Columns are based on ultra-pure (purity > 99.999%) spherical and totally porous silica, unique bonding chemistry and proprietary surface modification techniques, producing excellent peak shape, column efficiency and exceptional lot-to-lot reproducibility. Ultisil column is the best choice for method development. owing to complete bonding chemistries and stable performance

Features

  • Ultra-pure spherical porous silica, purity > 99.999%
  • Wide pH range: 2.0-8.0
  • High efficiency: theoretical plate > 80000/m
  • Excellent peak symmetry: tailing factor=0.95~1.05
  • Exceptional lot-to-lot reproducibility

Ultisil HPLC Column Packing Materials

Trace Amount Metal Contents Test

A useful chromatographic test of trace amount of metal contents in the column is to compare the peak symmetry of one pair of positional isomers, 4,4’-dipyridyl and 2,2’-dipyridyl, and a neutral chelating reagent, 1,2-dihydroxylnaphthalene. 4,4’-dipyridyl, which cannot form chelating complex with metal, is used as a reference. 2,2’-dipyridyl and 1,2-dihydroxylnaphthalene, which are chelating reagents, are sensitive to trace amount metal in silica. When a C18 column based on type A silica or other so-called type B silica with higher metal content is used, the peaks of 2,2’-dipyridyl and 1,2-dihydroxylnaphthalene would tail or even totally disappear.

Column:

Ultisil® XB-C18, 4.6 ×150 mm, 5 μm

Mobile Phase

20 mM phosphate(pH 7.6) / methanol=55/45

Flow Rate

1.0 mL/min

Detector

215 nm

Temperature:

25°C

Injection Volume

1 μL

Samples:

1) 4,4’-Dipyridyl

2) 2,2’-Dipyridyl

3) 1,2-Dihydroxylnaphthalene

 

 

 

 

Conclusion: Ultisi XB-C18 provides good peak shapes in the separation of these three compounds under pH 7.6, which indicates Ultisil silica contains hardly any metals.

Brand: Ultisil

Phase: LP-C18

Particle Size: 3.5µm

Pore Size: 120Å

USP Classification: L1

Separation Mode: Reversed Mode

pH Range: 0.5-8.0

Surface Area: 320m2/g

Carbon Load: 10%

Max.Pressure: 60Mpa

Endcapped: No

Max.Temp.: 70°C(pH≤6.5) and 40°C(pH>6.5)

Particle Shape: Spherical

Similar Columns:

  • Agilent ZORBAX SB-C18
  • Agilent ZORBAX Rx C18
  • Waters XSelect HSS-C18 SB

(Note: The above cross reference indicates alternative column(s) that will likely give a similar selectivity. There is no guarantee of 100% substitution and thus is for your reference only.)

Product Description


Ultisil Series HPLC Columns are based on ultra-pure (purity > 99.999%) spherical and totally porous silica, unique bonding chemistry and proprietary surface modification techniques, producing excellent peak shape, column efficiency and exceptional lot-to-lot reproducibility. Ultisil column is the best choice for method development. owing to complete bonding chemistries and stable performance

Features

  • Ultra-pure spherical porous silica, purity > 99.999%
  • Wide pH range: 2.0-8.0
  • High efficiency: theoretical plate > 80000/m
  • Excellent peak symmetry: tailing factor=0.95~1.05
  • Exceptional lot-to-lot reproducibility

Ultisil HPLC Column Packing Materials

Trace Amount Metal Contents Test

A useful chromatographic test of trace amount of metal contents in the column is to compare the peak symmetry of one pair of positional isomers, 4,4’-dipyridyl and 2,2’-dipyridyl, and a neutral chelating reagent, 1,2-dihydroxylnaphthalene. 4,4’-dipyridyl, which cannot form chelating complex with metal, is used as a reference. 2,2’-dipyridyl and 1,2-dihydroxylnaphthalene, which are chelating reagents, are sensitive to trace amount metal in silica. When a C18 column based on type A silica or other so-called type B silica with higher metal content is used, the peaks of 2,2’-dipyridyl and 1,2-dihydroxylnaphthalene would tail or even totally disappear.

Column:

Ultisil® XB-C18, 4.6 ×150 mm, 5 μm

Mobile Phase

20 mM phosphate(pH 7.6) / methanol=55/45

Flow Rate

1.0 mL/min

Detector

215 nm

Temperature:

25°C

Injection Volume

1 μL

Samples:

1) 4,4’-Dipyridyl

2) 2,2’-Dipyridyl

3) 1,2-Dihydroxylnaphthalene

 

 

 

 

Conclusion: Ultisi XB-C18 provides good peak shapes in the separation of these three compounds under pH 7.6, which indicates Ultisil silica contains hardly any metals.

Specifications

Brand: Ultisil

Phase: LP-C18

Particle Size: 3.5µm

Pore Size: 120Å

USP Classification: L1

Separation Mode: Reversed Mode

pH Range: 0.5-8.0

Surface Area: 320m2/g

Carbon Load: 10%

Max.Pressure: 60Mpa

Endcapped: No

Max.Temp.: 70°C(pH≤6.5) and 40°C(pH>6.5)

Particle Shape: Spherical

Similar Columns:

  • Agilent ZORBAX SB-C18
  • Agilent ZORBAX Rx C18
  • Waters XSelect HSS-C18 SB

(Note: The above cross reference indicates alternative column(s) that will likely give a similar selectivity. There is no guarantee of 100% substitution and thus is for your reference only.)

Documents