P/N: H00201-31937

Ultisil DLC XB-C18, 5μm, 4.6×50mm

Regular price $500.00 USD
Sale price $500.00 USD Regular price
Sale Sold out
Unit price
/per 
This is a pre order item. We will ship it when it comes in stock.

The diamond coating technology enhances the inner surface of the chromatography column with strong hydrophobicity, which overcomes the adverse effects of the column wall on separation.The high hardness and significant tensile properties of the diamond coating resolve the conflict between column mechanical strength and the influence of metal ions on separation. DLC HPLC Columns are ideal for preparation and purification of biological samples, such as proteins, polysaccharides, and nucleic acids.

Ultisil DLC XB-C18 is one of the most versatile C18 analytical columns on the market. It features advanced bonding and double-endcapping technology, delivering nearly perfect peak shapes. This column is ideal for analyzing complex matrix samples and provides excellent peak shapes for acidic and basic compounds. It is particularly effective for the separation of traditional Chinese medicine compounds.

Pairs well with

The Ultimate Experience of DLC Columns

  • Enhancing the inner surface of the chromatography column with strong hydrophobicity overcomes the adverse effects of the column wall on separation.
  • The high hardness and significant tensile properties of the diamond coating resolve the conflict between column mechanical strength and the influence of metal ions on separation.
  • Ideal for preparation and purification of biological samples, such as proteins, polysaccharides, and nucleic acids.

Detection of Bovine Serum Albumin

Sample Solution:A precise amount of Bovine Serum Albumin (BSA) was accurately weighed, dissolved in the mobile phase, and diluted to achieve a sample solution in which every 1mL contained 0.1mg of the sample

Conclusion: The Diamond like carbon column exhibited significantly increased response values.

Detection of Dexamethasone sodium phosphate

      Conclusion: 

      1.The diamond column minimizes the specific adsorption behavior of the chromatographic column tube, achieving efficient separation while showing higher sensitivity and response values.

      2. The peak signal of the diamond column can be increased several times, indicating that it has obvious advantages in testing metal-sensitive compounds.

          Brand: Ultisil

          Phase: XB-C18

          Particle Size: 5μm

          Pore Size: 120Å

          USP Classification: L1

          Separation Mode: Reversed Mode

          pH Range: 2.0-8.0

          Surface Area: 320m2/g

          Carbon Load: 17%

          Max.Pressure: 40Mpa

          Endcapped: Yes

          Max.Temp.: 60°C(pH≤6.5) and 40°C(pH>6.5)

          Particle Shape: Spherical

          Column Cross Reference:
          (Please kindly note that columns among brands are never 100% the same. The below cross reference list indicates alternatives column(s) that will likely give a similar selectivity. Inevitable differences in retention time, resolution and theoretical plate count exist and may affect the results for certain circumstances.)

          • Agilent ZORBAX Eclipse XDB-C18
          • Agilent ZORBAX TYPE A Silica C18
          • Agilent Pursuit XRs C18
          • Agilent Pursuit XRs Ultra C18
          • Agilent HC (2)/TC (2) HC-C18 (2)
          • Phenomenex Columbus C18
          • Phenomenex Luna C18
          • Phenomenex Luna Omega C18
          • Phenomenex Prodigy ODS-2
          • Sepax Sepax GP-C18
          • Sepax Sepax Bio-C18-200
          • Sepax Sepax Sapphire C18
          • Supelco Discovery C18
          • Supelco Discovery HS C18
          • Thermo BETASIL C18
          • Thermo Fluophase RP 100A perfluorohexyl
          • Thermo Hypersil GOLD C18
          • Thermo Hypersil ODS (C18)
          • Thermo Hypersil ODS-2 (C18)
          • Thermo Acclaim 120 C18
          • Thermo Acclaim AMG C18
          • Thermo HyPURITY C18
          • Thermo HyPURITY Aquastar
          • Thermo Syncronis C18
          • Waters XBridge BEH 130-C18 (PST)
          • Waters XSelect HSS-C18
          • Waters Symmetry C18
          • Waters Sunfire C18
          • Waters Spherisorb ODS2 fully end capped
          • Waters Delta-Pak C18 (100A)
          • Waters BioSuite C18 PA-A
          Product Description

          The Ultimate Experience of DLC Columns

          • Enhancing the inner surface of the chromatography column with strong hydrophobicity overcomes the adverse effects of the column wall on separation.
          • The high hardness and significant tensile properties of the diamond coating resolve the conflict between column mechanical strength and the influence of metal ions on separation.
          • Ideal for preparation and purification of biological samples, such as proteins, polysaccharides, and nucleic acids.

          Detection of Bovine Serum Albumin

          Sample Solution:A precise amount of Bovine Serum Albumin (BSA) was accurately weighed, dissolved in the mobile phase, and diluted to achieve a sample solution in which every 1mL contained 0.1mg of the sample

          Conclusion: The Diamond like carbon column exhibited significantly increased response values.

          Detection of Dexamethasone sodium phosphate

              Conclusion: 

              1.The diamond column minimizes the specific adsorption behavior of the chromatographic column tube, achieving efficient separation while showing higher sensitivity and response values.

              2. The peak signal of the diamond column can be increased several times, indicating that it has obvious advantages in testing metal-sensitive compounds.

                  Specifications

                  Brand: Ultisil

                  Phase: XB-C18

                  Particle Size: 5μm

                  Pore Size: 120Å

                  USP Classification: L1

                  Separation Mode: Reversed Mode

                  pH Range: 2.0-8.0

                  Surface Area: 320m2/g

                  Carbon Load: 17%

                  Max.Pressure: 40Mpa

                  Endcapped: Yes

                  Max.Temp.: 60°C(pH≤6.5) and 40°C(pH>6.5)

                  Particle Shape: Spherical

                  Column Cross Reference:
                  (Please kindly note that columns among brands are never 100% the same. The below cross reference list indicates alternatives column(s) that will likely give a similar selectivity. Inevitable differences in retention time, resolution and theoretical plate count exist and may affect the results for certain circumstances.)

                  • Agilent ZORBAX Eclipse XDB-C18
                  • Agilent ZORBAX TYPE A Silica C18
                  • Agilent Pursuit XRs C18
                  • Agilent Pursuit XRs Ultra C18
                  • Agilent HC (2)/TC (2) HC-C18 (2)
                  • Phenomenex Columbus C18
                  • Phenomenex Luna C18
                  • Phenomenex Luna Omega C18
                  • Phenomenex Prodigy ODS-2
                  • Sepax Sepax GP-C18
                  • Sepax Sepax Bio-C18-200
                  • Sepax Sepax Sapphire C18
                  • Supelco Discovery C18
                  • Supelco Discovery HS C18
                  • Thermo BETASIL C18
                  • Thermo Fluophase RP 100A perfluorohexyl
                  • Thermo Hypersil GOLD C18
                  • Thermo Hypersil ODS (C18)
                  • Thermo Hypersil ODS-2 (C18)
                  • Thermo Acclaim 120 C18
                  • Thermo Acclaim AMG C18
                  • Thermo HyPURITY C18
                  • Thermo HyPURITY Aquastar
                  • Thermo Syncronis C18
                  • Waters XBridge BEH 130-C18 (PST)
                  • Waters XSelect HSS-C18
                  • Waters Symmetry C18
                  • Waters Sunfire C18
                  • Waters Spherisorb ODS2 fully end capped
                  • Waters Delta-Pak C18 (100A)
                  • Waters BioSuite C18 PA-A
                  Documents