P/N: 0004-04041

Advanchrom SCX, 5µm, 4.6×150mm (1pcs/pk)

Regular price $1,450.00 USD
Sale price $1,450.00 USD Regular price
Sale Sold out
Unit price
/per 
This is a pre order item. We will ship it when it comes in stock.

Advanchrom SCX is a high-performance strong cation exchange chromatography column designed for protein separation. It is built on advanced monodisperse nonporous polymer microspheres and utilizes a proprietary surface bonding technology. This column is ideal for the separation and characterization of charge variants in monoclonal antibodies, bispecific antibodies, fusion proteins, and antibody–drug conjugates (ADCs).

Quantity: 1 pcs/pk

Pairs well with

Advanchrom SCX is a high-performance column designed for protein separation. It is built on advanced monodisperse nonporous polymer microspheres and utilizes a proprietary surface bonding technology. This column is ideal for the separation and characterization of charge variants in monoclonal antibodies, bispecific antibodies, fusion proteins, and antibody–drug conjugates (ADCs).

Features:

  • High resolution and outstanding selectivity for charge variants of antibody molecules
  • Advanced polymer bead technology, yielding high eciency and excellent batch-to-batch consistency
  • Proprietary surface modification, oering minimized non-specific adsorption and high recovery rates

Application Examples

Analysis of NIST mAb Charge Variant

  • Column: Advanchrom SCX (4.6×150 mm, 5 μm)
  • Mobile Phase: A) 20 mM MES (pH 6.5); B) 20 mM MES (pH 6.5) + 0.5 M NaCl
  • Flow Rate: 0.3 mL/min
  • Detector Wavelength: 280 nm
  • Column Temperature: 30 °C
  • Injection Volume: 2 μL
  • Sample Concentration: 10 mg/mL
  • Gradient:
    t (min) A% B%
    0 90 10
    3 70 30
Chromatogram of NIST mAb

Analysis of Rituximab Charge Variant

  • Column: Advanchrom SCX (4.6×150 mm, 5 μm)
  • Mobile Phase: A) 20 mM MES (pH 6.5); B) 20 mM MES (pH 6.5) + 0.3 M NaCl
  • Flow Rate: 0.5 mL/min
  • Detector Wavelength: 280 nm
  • Column Temperature: 30 °C
  • Injection Volume: 10 μL
  • Sample Concentration: 1 mg/mL
  • Gradient:
    t (min) A% B%
    0 80 20
    20 65 35
    20.1 0 100
    23 0 100
    23.1 80 20
    30 80 20
Chromatogram of Rituximab

Brand: Advanchrom

Phase: Adv-SCX

Particle Size: 5µm

Pore Size:

USP Classification: L9

Separation Mode: Ion Exchange

pH Range: 2.0-12.0

Surface Area:

Carbon Load:

Max.Pressure: 6000psi

Endcapped:

Max.Temp.: 60℃

Particle Shape: Non-porous

Product Description

Advanchrom SCX is a high-performance column designed for protein separation. It is built on advanced monodisperse nonporous polymer microspheres and utilizes a proprietary surface bonding technology. This column is ideal for the separation and characterization of charge variants in monoclonal antibodies, bispecific antibodies, fusion proteins, and antibody–drug conjugates (ADCs).

Features:

  • High resolution and outstanding selectivity for charge variants of antibody molecules
  • Advanced polymer bead technology, yielding high eciency and excellent batch-to-batch consistency
  • Proprietary surface modification, oering minimized non-specific adsorption and high recovery rates

Application Examples

Analysis of NIST mAb Charge Variant

  • Column: Advanchrom SCX (4.6×150 mm, 5 μm)
  • Mobile Phase: A) 20 mM MES (pH 6.5); B) 20 mM MES (pH 6.5) + 0.5 M NaCl
  • Flow Rate: 0.3 mL/min
  • Detector Wavelength: 280 nm
  • Column Temperature: 30 °C
  • Injection Volume: 2 μL
  • Sample Concentration: 10 mg/mL
  • Gradient:
    t (min) A% B%
    0 90 10
    3 70 30
Chromatogram of NIST mAb

Analysis of Rituximab Charge Variant

  • Column: Advanchrom SCX (4.6×150 mm, 5 μm)
  • Mobile Phase: A) 20 mM MES (pH 6.5); B) 20 mM MES (pH 6.5) + 0.3 M NaCl
  • Flow Rate: 0.5 mL/min
  • Detector Wavelength: 280 nm
  • Column Temperature: 30 °C
  • Injection Volume: 10 μL
  • Sample Concentration: 1 mg/mL
  • Gradient:
    t (min) A% B%
    0 80 20
    20 65 35
    20.1 0 100
    23 0 100
    23.1 80 20
    30 80 20
Chromatogram of Rituximab
Specifications

Brand: Advanchrom

Phase: Adv-SCX

Particle Size: 5µm

Pore Size:

USP Classification: L9

Separation Mode: Ion Exchange

pH Range: 2.0-12.0

Surface Area:

Carbon Load:

Max.Pressure: 6000psi

Endcapped:

Max.Temp.: 60℃

Particle Shape: Non-porous

Documents

Purchasing outside the United States?

Looking to purchase this product for delivery outside the U.S.? Find your local distributor, or request a quotation from our team if no distributor is available in your country.