Advanchrom SCX is a high-performance column designed for protein separation. It is built on advanced monodisperse nonporous polymer microspheres and utilizes a proprietary surface bonding technology. This column is ideal for the separation and characterization of charge variants in monoclonal antibodies, bispecific antibodies, fusion proteins, and antibody–drug conjugates (ADCs).
Features:
- High resolution and outstanding selectivity for charge variants of antibody molecules
- Advanced polymer bead technology, yielding high eciency and excellent batch-to-batch consistency
- Proprietary surface modification, oering minimized non-specific adsorption and high recovery rates
Application Examples
Analysis of NIST mAb Charge Variant
- Column: Advanchrom SCX (4.6×150 mm, 5 μm)
- Mobile Phase: A) 20 mM MES (pH 6.5); B) 20 mM MES (pH 6.5) + 0.5 M NaCl
- Flow Rate: 0.3 mL/min
- Detector Wavelength: 280 nm
- Column Temperature: 30 °C
- Injection Volume: 2 μL
- Sample Concentration: 10 mg/mL
- Gradient:
t (min) A% B% 0 90 10 3 70 30

Analysis of Rituximab Charge Variant
- Column: Advanchrom SCX (4.6×150 mm, 5 μm)
- Mobile Phase: A) 20 mM MES (pH 6.5); B) 20 mM MES (pH 6.5) + 0.3 M NaCl
- Flow Rate: 0.5 mL/min
- Detector Wavelength: 280 nm
- Column Temperature: 30 °C
- Injection Volume: 10 μL
- Sample Concentration: 1 mg/mL
- Gradient:
t (min) A% B% 0 80 20 20 65 35 20.1 0 100 23 0 100 23.1 80 20 30 80 20

Brand: Advanchrom
Phase: Adv-SCX
Particle Size: 5µm
Pore Size:
USP Classification: L9
Separation Mode: Ion Exchange
pH Range: 2.0-12.0
Surface Area:
Carbon Load:
Max.Pressure: 6000psi
Endcapped:
Max.Temp.: 60℃
Particle Shape: Non-porous
Advanchrom SCX is a high-performance column designed for protein separation. It is built on advanced monodisperse nonporous polymer microspheres and utilizes a proprietary surface bonding technology. This column is ideal for the separation and characterization of charge variants in monoclonal antibodies, bispecific antibodies, fusion proteins, and antibody–drug conjugates (ADCs).
Features:
- High resolution and outstanding selectivity for charge variants of antibody molecules
- Advanced polymer bead technology, yielding high eciency and excellent batch-to-batch consistency
- Proprietary surface modification, oering minimized non-specific adsorption and high recovery rates
Application Examples
Analysis of NIST mAb Charge Variant
- Column: Advanchrom SCX (4.6×150 mm, 5 μm)
- Mobile Phase: A) 20 mM MES (pH 6.5); B) 20 mM MES (pH 6.5) + 0.5 M NaCl
- Flow Rate: 0.3 mL/min
- Detector Wavelength: 280 nm
- Column Temperature: 30 °C
- Injection Volume: 2 μL
- Sample Concentration: 10 mg/mL
- Gradient:
t (min) A% B% 0 90 10 3 70 30

Analysis of Rituximab Charge Variant
- Column: Advanchrom SCX (4.6×150 mm, 5 μm)
- Mobile Phase: A) 20 mM MES (pH 6.5); B) 20 mM MES (pH 6.5) + 0.3 M NaCl
- Flow Rate: 0.5 mL/min
- Detector Wavelength: 280 nm
- Column Temperature: 30 °C
- Injection Volume: 10 μL
- Sample Concentration: 1 mg/mL
- Gradient:
t (min) A% B% 0 80 20 20 65 35 20.1 0 100 23 0 100 23.1 80 20 30 80 20

Brand: Advanchrom
Phase: Adv-SCX
Particle Size: 5µm
Pore Size:
USP Classification: L9
Separation Mode: Ion Exchange
pH Range: 2.0-12.0
Surface Area:
Carbon Load:
Max.Pressure: 6000psi
Endcapped:
Max.Temp.: 60℃
Particle Shape: Non-porous
Purchasing outside the United States?