
Normal/Reversed Phase Columns
P/N: H00216-21033
Ultisil XB-C4, 3μm, 4.0×200mm
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.
P/N: H00216-21032
Ultisil XB-C4, 3μm, 4.0×150mm
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.
P/N: H00216-21064
Ultisil XB-C4, 3μm, 3.9×150mm
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.
P/N: H00216-21031
Ultisil XB-C4, 3μm, 4.0×125mm
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.
P/N: H00216-21030
Ultisil XB-C4, 3μm, 4.0×100mm
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.
P/N: H00216-21029
Ultisil XB-C4, 3μm, 4.0×75mm
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.
P/N: H00216-21028
Ultisil XB-C4, 3μm, 4.0×50mm
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.
P/N: H00216-21027
Ultisil XB-C4, 3μm, 4.0×30mm
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.
P/N: H00216-21025
Ultisil XB-C4, 3μm, 3.0×250mm
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.
P/N: H00216-21024
Ultisil XB-C4, 3μm, 3.0×200mm
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.
P/N: H00216-21023
Ultisil XB-C4, 3μm, 3.0×150mm
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.
P/N: H00216-21022
Ultisil XB-C4, 3μm, 3.0×125mm
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.
P/N: H00216-21021
Ultisil XB-C4, 3μm, 3.0×100mm
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.
P/N: H00216-21020
Ultisil XB-C4, 3μm, 3.0×75mm
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.
P/N: H00216-21019
Ultisil XB-C4, 3μm, 3.0×50mm
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.
P/N: H00216-21018
Ultisil XB-C4, 3μm, 3.0×30mm
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.
P/N: H00216-21016
Ultisil XB-C4, 3μm, 2.1×250mm
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.
P/N: H00216-21015
Ultisil XB-C4, 3μm, 2.1×200mm
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.
P/N: H00216-21014
Ultisil XB-C4, 3μm, 2.1×150mm
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.
P/N: H00216-21013
Ultisil XB-C4, 3μm, 2.1×125mm
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.
P/N: H00216-21012
Ultisil XB-C4, 3μm, 2.1×100mm
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.
P/N: H00216-21011
Ultisil XB-C4, 3μm, 2.1×75mm
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.
P/N: H00216-21010
Ultisil XB-C4, 3μm, 2.1×50mm
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.
P/N: H00216-21068
Ultisil XB-C4, 3μm, 2.1×33mm
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.
Column Specifications
C18 Columns
Series | Column | pH Range | Max Temperature | Max Pressure Tolerance |
Ultisil Series | Ultisil LP-C18 | 0.5-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
Ultisil LP-Aq | 1.0-8.0 | |||
Ultisil XB-C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
Ultisil AQ-C18 | 2.0-8.0 | |||
Ultisil Plus C18 | 2.0-8.0 | |||
Ultisil Alk C18 | 2.0-8.0 | |||
Ultisil PAH | 2.0-8.0 | |||
Ultisil Polar RP | 2.0-8.0 | |||
Ultisil ODS-3 | 2.0-8.0 | |||
Ultisil XS-C18 | 2.0-8.0 | |||
Ultisil Plus LP-C18 | 0.5-8.0 | |||
Xtimate Series | Xtimate C18 | 1.0-12.5 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
Xtimate Polar RP | 1.0-12.5 | |||
Blossmate Series | Blossmate C18 | 2.0-8.0 | 60 °C | 40 MPa |
Blossmate Aqs C18 | 2.0-8.0 | |||
Blossmate ST-C18 | 1.0-11.0 | |||
Topsil Series | Topsil C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa |
Welchrom Series | Welchrom C18 | 2.0-8.0 | 60 °C | 40 MPa |
Welchrom Vantage C18 | 2.0-8.0 | 60 °C | 40 MPa | |
Boltimate Series | Boltimate C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
60 MPa |
Boltimate EXT-C18 | 1.5-12.0 | |||
Boltimate LP-C18 | 1.0-8.0 |
C8, C4, C3, C1 and Phenyl Columns
Series | Column | pH Range | Max Temperature | Max Pressure Tolerance |
Ultisil Series | Ultisil XB-C8 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
Ultisil LP-C8 | 1.0-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
Ultisil F-C8 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
Ultisil Plus-C8 | 2.0-8.0 | |||
Ultisil XB-Phenyl | 2.0-8.0 | |||
Ultisil Phenyl-Ether | 2.0-8.0 | |||
Ultisil PFP | 2.0-8.0 | |||
Ultisil Plus-phenyl | 2.0-8.0 | |||
Ultisil XB-C4 | 2.0-8.0 | |||
Ultisil LP-C3 | 1.0-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
Ultisil XB-C30 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
Ultisil XB-C1 | 2.0-8.0 | |||
Ultisil XB-CN | 2.0-8.0 | |||
Ultisil LP-CN | 1.0-8.0 | |||
Xtimate Series | Xtimate C8 | 1.0-12.5 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
Xtimate Phenyl-Hexyl | 1.0-12.5 | |||
Xtimate C4 | 1.0-12.5 | |||
Blossmate Series | Blossmate C4 | 2.0-8.0 | 60 °C | 40 MPa |
Blossmate Phenyl | 2.0-8.0 | |||
Topsil Series | Topsil C8 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa |
Topsil phenyl-Hexyl | 2.0-8.0 | |||
Topsil CN | 2.0-8.0 | |||
Welchrom Series | Welchrom C8 | 2.0-8.0 | 60 °C | 40 MPa |
Boltimate Series | Boltimate C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
60 MPa |
Boltimate Phenyl-Hexyl | 2.0-8.0 | |||
Boltimate EXT-C18 | 1.5-12 | |||
Boltimate EXT-PFP | 1.5-10 | |||
Boltimate HILIC | 2.0-8.0 | |||
Boltimate LP-C18 | 1.0-8.0 | |||
Boltimate C8 | 2.0-8.0 | |||
Boltimate Phenyl | 2.0-8.0 |
Normal-Phase Columns
Series | Column | pH Range | Max Temperature | Max Pressure Tolerance |
Ultisil Series | Ultisil SiO2 | 2.0-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
Ultisil Diol | 2.0-8.0 | |||
Ultisil XB-NH2 | 2.0-8.0 | |||
Ultisil XB-CN | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
Topsil Series | Topsil Silica | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa |
Topsil NH2 | 2.0-8.0 |
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device