Normal/Reversed Phase Columns
P/N: H00216-21039
Ultisil XB-C4, 3μm, 4.6×100mm (1pcs/pk)
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.Quantit...
P/N: H00216-21038
Ultisil XB-C4, 3μm, 4.6×75mm (1pcs/pk)
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.Quantit...
P/N: H00216-21037
Ultisil XB-C4, 3μm, 4.6×50mm (1pcs/pk)
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.Quantit...
P/N: H00216-21071
Ultisil XB-C4, 3μm, 4.6×33mm (1pcs/pk)
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.Quantit...
P/N: H00216-21036
Ultisil XB-C4, 3μm, 4.6×30mm (1pcs/pk)
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.Quantit...
P/N: H00216-21034
Ultisil XB-C4, 3μm, 4.0×250mm (1pcs/pk)
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.Quantit...
P/N: H00216-21066
Ultisil XB-C4, 3μm, 3.9×250mm (1pcs/pk)
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.Quantit...
P/N: H00216-21033
Ultisil XB-C4, 3μm, 4.0×200mm (1pcs/pk)
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.Quantit...
P/N: H00216-21032
Ultisil XB-C4, 3μm, 4.0×150mm (1pcs/pk)
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.Quantit...
P/N: H00216-21064
Ultisil XB-C4, 3μm, 3.9×150mm (1pcs/pk)
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.Quantit...
P/N: H00216-21031
Ultisil XB-C4, 3μm, 4.0×125mm (1pcs/pk)
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.Quantit...
P/N: H00216-21030
Ultisil XB-C4, 3μm, 4.0×100mm (1pcs/pk)
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.Quantit...
P/N: H00216-21029
Ultisil XB-C4, 3μm, 4.0×75mm (1pcs/pk)
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.Quantit...
P/N: H00216-21028
Ultisil XB-C4, 3μm, 4.0×50mm (1pcs/pk)
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.Quantit...
P/N: H00216-21027
Ultisil XB-C4, 3μm, 4.0×30mm (1pcs/pk)
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.Quantit...
P/N: H00216-21025
Ultisil XB-C4, 3μm, 3.0×250mm (1pcs/pk)
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.Quantit...
P/N: H00216-21024
Ultisil XB-C4, 3μm, 3.0×200mm (1pcs/pk)
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.Quantit...
P/N: H00216-21023
Ultisil XB-C4, 3μm, 3.0×150mm (1pcs/pk)
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.Quantit...
P/N: H00216-21022
Ultisil XB-C4, 3μm, 3.0×125mm (1pcs/pk)
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.Quantit...
P/N: H00216-21021
Ultisil XB-C4, 3μm, 3.0×100mm (1pcs/pk)
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.Quantit...
P/N: H00216-21020
Ultisil XB-C4, 3μm, 3.0×75mm (1pcs/pk)
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.Quantit...
P/N: H00216-21019
Ultisil XB-C4, 3μm, 3.0×50mm (1pcs/pk)
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.Quantit...
P/N: H00216-21018
Ultisil XB-C4, 3μm, 3.0×30mm (1pcs/pk)
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.Quantit...
P/N: H00216-21016
Ultisil XB-C4, 3μm, 2.1×250mm (1pcs/pk)
Ultisil XB-C4 column exhibits strong retention for both hydrophobic and polar compounds, making it an ideal choice for substances that retain too strongly on conventional C8 and C18 columns.Quantit...
Column Specifications
C18 Columns
| Series | Column | pH Range | Max Temperature | Max Pressure Tolerance |
| Ultisil Series | Ultisil LP-C18 | 0.5-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
| Ultisil LP-Aq | 1.0-8.0 | |||
| Ultisil XB-C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
| Ultisil AQ-C18 | 2.0-8.0 | |||
| Ultisil Plus C18 | 2.0-8.0 | |||
| Ultisil Alk C18 | 2.0-8.0 | |||
| Ultisil PAH | 2.0-8.0 | |||
| Ultisil Polar RP | 2.0-8.0 | |||
| Ultisil ODS-3 | 2.0-8.0 | |||
| Ultisil XS-C18 | 2.0-8.0 | |||
| Ultisil Plus LP-C18 | 0.5-8.0 | |||
| Xtimate Series | Xtimate C18 | 1.0-12.5 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
| Xtimate Polar RP | 1.0-12.5 | |||
| Blossmate Series | Blossmate C18 | 2.0-8.0 | 60 °C | 40 MPa |
| Blossmate Aqs C18 | 2.0-8.0 | |||
| Blossmate ST-C18 | 1.0-11.0 | |||
| Topsil Series | Topsil C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa |
| Welchrom Series | Welchrom C18 | 2.0-8.0 | 60 °C | 40 MPa |
| Welchrom Vantage C18 | 2.0-8.0 | 60 °C | 40 MPa | |
| Boltimate Series | Boltimate C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
60 MPa |
| Boltimate EXT-C18 | 1.5-12.0 | |||
| Boltimate LP-C18 | 1.0-8.0 |
C8, C4, C3, C1 and Phenyl Columns
| Series | Column | pH Range | Max Temperature | Max Pressure Tolerance |
| Ultisil Series | Ultisil XB-C8 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
| Ultisil LP-C8 | 1.0-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
| Ultisil F-C8 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
| Ultisil Plus-C8 | 2.0-8.0 | |||
| Ultisil XB-Phenyl | 2.0-8.0 | |||
| Ultisil Phenyl-Ether | 2.0-8.0 | |||
| Ultisil PFP | 2.0-8.0 | |||
| Ultisil Plus-phenyl | 2.0-8.0 | |||
| Ultisil XB-C4 | 2.0-8.0 | |||
| Ultisil LP-C3 | 1.0-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
| Ultisil XB-C30 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
| Ultisil XB-C1 | 2.0-8.0 | |||
| Ultisil XB-CN | 2.0-8.0 | |||
| Ultisil LP-CN | 1.0-8.0 | |||
| Xtimate Series | Xtimate C8 | 1.0-12.5 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
| Xtimate Phenyl-Hexyl | 1.0-12.5 | |||
| Xtimate C4 | 1.0-12.5 | |||
| Blossmate Series | Blossmate C4 | 2.0-8.0 | 60 °C | 40 MPa |
| Blossmate Phenyl | 2.0-8.0 | |||
| Topsil Series | Topsil C8 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa |
| Topsil phenyl-Hexyl | 2.0-8.0 | |||
| Topsil CN | 2.0-8.0 | |||
| Welchrom Series | Welchrom C8 | 2.0-8.0 | 60 °C | 40 MPa |
| Boltimate Series | Boltimate C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
60 MPa |
| Boltimate Phenyl-Hexyl | 2.0-8.0 | |||
| Boltimate EXT-C18 | 1.5-12 | |||
| Boltimate EXT-PFP | 1.5-10 | |||
| Boltimate HILIC | 2.0-8.0 | |||
| Boltimate LP-C18 | 1.0-8.0 | |||
| Boltimate C8 | 2.0-8.0 | |||
| Boltimate Phenyl | 2.0-8.0 |
Normal-Phase Columns
| Series | Column | pH Range | Max Temperature | Max Pressure Tolerance |
| Ultisil Series | Ultisil SiO2 | 2.0-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
| Ultisil Diol | 2.0-8.0 | |||
| Ultisil XB-NH2 | 2.0-8.0 | |||
| Ultisil XB-CN | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
| Topsil Series | Topsil Silica | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa |
| Topsil NH2 | 2.0-8.0 |
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device