Normal/Reversed Phase Columns
P/N: H02600-21108
Ultisil SiO2, 5μm, 30×250mm, 120Å (1pcs/pk)
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...
P/N: H02600-21107
Ultisil SiO2, 5μm, 30×150mm, 120Å (1pcs/pk)
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...
P/N: H02600-21106
Ultisil SiO2, 5μm, 21.2×250mm, 120Å (1pcs/pk)
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...
P/N: H02600-21105
Ultisil SiO2, 5μm, 21.2×150mm, 120Å (1pcs/pk)
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...
P/N: H02600-21104
Ultisil SiO2, 5μm, 21.2×50mm, 120Å (1pcs/pk)
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...
P/N: H02600-21103
Ultisil SiO2, 5μm, 10×300mm, 120Å (1pcs/pk)
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...
P/N: H02600-21102
Ultisil SiO2, 5μm, 10×250mm, 120Å (1pcs/pk)
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...
P/N: H02600-21101
Ultisil SiO2, 5μm, 10×150mm, 120Å (1pcs/pk)
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...
P/N: H02600-21100
Ultisil SiO2, 5μm, 10×100mm, 120Å (1pcs/pk)
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...
P/N: H00200-33052
Ultisil SiO2, 5μm, 300Å, 7.8×300mm (1pcs/pk)
Ultisil SiO2 column utilizes B-type ultrapure fully porous spherical silica gel (purity >99.1048%) as the packing material, featuring low acidity and low metal content. It is suitable for the se...
P/N: H00200-33051
Ultisil SiO2, 5μm, 300Å, 7.8×250mm (1pcs/pk)
Ultisil SiO2 column utilizes B-type ultrapure fully porous spherical silica gel (purity >99.1047%) as the packing material, featuring low acidity and low metal content. It is suitable for the se...
P/N: H00200-33048
Ultisil SiO2, 5μm, 300Å, 7.8×50mm (1pcs/pk)
Ultisil SiO2 column utilizes B-type ultrapure fully porous spherical silica gel (purity >99.1049%) as the packing material, featuring low acidity and low metal content. It is suitable for the se...
P/N: H00200-33043
Ultisil SiO2, 5μm, 300Å, 4.6×250mm (1pcs/pk)
Ultisil SiO2 column utilizes B-type ultrapure fully porous spherical silica gel (purity >99.1046%) as the packing material, featuring low acidity and low metal content. It is suitable for the se...
P/N: H00200-23043
Ultisil SiO2, 3μm, 300Å, 4.6×250mm (1pcs/pk)
Ultisil SiO2 column utilizes B-type ultrapure fully porous spherical silica gel (purity >99.1015%) as the packing material, featuring low acidity and low metal content. It is suitable for the se...
P/N: H00200-41044
Ultisil SiO2, 10μm, 4.6×300mm (1pcs/pk)
Ultisil SiO2 column utilizes B-type ultrapure fully porous spherical silica gel (purity >99.999%) as the packing material, featuring low acidity and low metal content. It is suitable for the sep...
P/N: H00200-41043
Ultisil SiO2, 10μm, 4.6×250mm (1pcs/pk)
Ultisil SiO2 column utilizes B-type ultrapure fully porous spherical silica gel (purity >99.999%) as the packing material, featuring low acidity and low metal content. It is suitable for the sep...
P/N: H00200-41042
Ultisil SiO2, 10μm, 4.6×200mm (1pcs/pk)
Ultisil SiO2 column utilizes B-type ultrapure fully porous spherical silica gel (purity >99.999%) as the packing material, featuring low acidity and low metal content. It is suitable for the sep...
P/N: H00200-41041
Ultisil SiO2, 10μm, 4.6×150mm (1pcs/pk)
Ultisil SiO2 column utilizes B-type ultrapure fully porous spherical silica gel (purity >99.999%) as the packing material, featuring low acidity and low metal content. It is suitable for the sep...
P/N: H00200-41035
Ultisil SiO2, 10μm, 4.0×300mm (1pcs/pk)
Ultisil SiO2 column utilizes B-type ultrapure fully porous spherical silica gel (purity >99.999%) as the packing material, featuring low acidity and low metal content. It is suitable for the sep...
P/N: H00200-41034
Ultisil SiO2, 10μm, 4.0×250mm (1pcs/pk)
Ultisil SiO2 column utilizes B-type ultrapure fully porous spherical silica gel (purity >99.999%) as the packing material, featuring low acidity and low metal content. It is suitable for the sep...
P/N: H00200-41067
Ultisil SiO2, 10μm, 3.9×300mm (1pcs/pk)
Ultisil SiO2 column utilizes B-type ultrapure fully porous spherical silica gel (purity >99.999%) as the packing material, featuring low acidity and low metal content. It is suitable for the sep...
P/N: H00200-31052
Ultisil SiO2, 5μm, 7.8×300mm (1pcs/pk)
Ultisil SiO2 column utilizes B-type ultrapure fully porous spherical silica gel (purity >99.1074%) as the packing material, featuring low acidity and low metal content. It is suitable for the se...
P/N: H00200-31051
Ultisil SiO2, 5μm, 7.8×250mm (1pcs/pk)
Ultisil SiO2 column utilizes B-type ultrapure fully porous spherical silica gel (purity >99.1073%) as the packing material, featuring low acidity and low metal content. It is suitable for the se...
P/N: H00200-31050
Ultisil SiO2, 5μm, 7.8×150mm (1pcs/pk)
Ultisil SiO2 column utilizes B-type ultrapure fully porous spherical silica gel (purity >99.1072%) as the packing material, featuring low acidity and low metal content. It is suitable for the se...
Column Specifications
C18 Columns
| Series | Column | pH Range | Max Temperature | Max Pressure Tolerance |
| Ultisil Series | Ultisil LP-C18 | 0.5-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
| Ultisil LP-Aq | 1.0-8.0 | |||
| Ultisil XB-C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
| Ultisil AQ-C18 | 2.0-8.0 | |||
| Ultisil Plus C18 | 2.0-8.0 | |||
| Ultisil Alk C18 | 2.0-8.0 | |||
| Ultisil PAH | 2.0-8.0 | |||
| Ultisil Polar RP | 2.0-8.0 | |||
| Ultisil ODS-3 | 2.0-8.0 | |||
| Ultisil XS-C18 | 2.0-8.0 | |||
| Ultisil Plus LP-C18 | 0.5-8.0 | |||
| Xtimate Series | Xtimate C18 | 1.0-12.5 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
| Xtimate Polar RP | 1.0-12.5 | |||
| Blossmate Series | Blossmate C18 | 2.0-8.0 | 60 °C | 40 MPa |
| Blossmate Aqs C18 | 2.0-8.0 | |||
| Blossmate ST-C18 | 1.0-11.0 | |||
| Topsil Series | Topsil C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa |
| Welchrom Series | Welchrom C18 | 2.0-8.0 | 60 °C | 40 MPa |
| Welchrom Vantage C18 | 2.0-8.0 | 60 °C | 40 MPa | |
| Boltimate Series | Boltimate C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
60 MPa |
| Boltimate EXT-C18 | 1.5-12.0 | |||
| Boltimate LP-C18 | 1.0-8.0 |
C8, C4, C3, C1 and Phenyl Columns
| Series | Column | pH Range | Max Temperature | Max Pressure Tolerance |
| Ultisil Series | Ultisil XB-C8 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
| Ultisil LP-C8 | 1.0-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
| Ultisil F-C8 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
| Ultisil Plus-C8 | 2.0-8.0 | |||
| Ultisil XB-Phenyl | 2.0-8.0 | |||
| Ultisil Phenyl-Ether | 2.0-8.0 | |||
| Ultisil PFP | 2.0-8.0 | |||
| Ultisil Plus-phenyl | 2.0-8.0 | |||
| Ultisil XB-C4 | 2.0-8.0 | |||
| Ultisil LP-C3 | 1.0-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
| Ultisil XB-C30 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
| Ultisil XB-C1 | 2.0-8.0 | |||
| Ultisil XB-CN | 2.0-8.0 | |||
| Ultisil LP-CN | 1.0-8.0 | |||
| Xtimate Series | Xtimate C8 | 1.0-12.5 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
| Xtimate Phenyl-Hexyl | 1.0-12.5 | |||
| Xtimate C4 | 1.0-12.5 | |||
| Blossmate Series | Blossmate C4 | 2.0-8.0 | 60 °C | 40 MPa |
| Blossmate Phenyl | 2.0-8.0 | |||
| Topsil Series | Topsil C8 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa |
| Topsil phenyl-Hexyl | 2.0-8.0 | |||
| Topsil CN | 2.0-8.0 | |||
| Welchrom Series | Welchrom C8 | 2.0-8.0 | 60 °C | 40 MPa |
| Boltimate Series | Boltimate C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
60 MPa |
| Boltimate Phenyl-Hexyl | 2.0-8.0 | |||
| Boltimate EXT-C18 | 1.5-12 | |||
| Boltimate EXT-PFP | 1.5-10 | |||
| Boltimate HILIC | 2.0-8.0 | |||
| Boltimate LP-C18 | 1.0-8.0 | |||
| Boltimate C8 | 2.0-8.0 | |||
| Boltimate Phenyl | 2.0-8.0 |
Normal-Phase Columns
| Series | Column | pH Range | Max Temperature | Max Pressure Tolerance |
| Ultisil Series | Ultisil SiO2 | 2.0-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
| Ultisil Diol | 2.0-8.0 | |||
| Ultisil XB-NH2 | 2.0-8.0 | |||
| Ultisil XB-CN | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
| Topsil Series | Topsil Silica | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa |
| Topsil NH2 | 2.0-8.0 |
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device