Normal/Reversed Phase Columns
P/N: H00259-31037
Ultisil LP-AQ, 5μm, 4.6×50mm
Ultisil LP-Aq is a HPLC column designed to withstand 100%–0% aqueous environments. Featuring short-chain alkyl bonding technology, it can withstand strong acidic conditions, maintaining high stabil...
P/N: H00259-31034
Ultisil LP-AQ, 5μm, 4.0×250mm
Ultisil LP-Aq is a HPLC column designed to withstand 100%–0% aqueous environments. Featuring short-chain alkyl bonding technology, it can withstand strong acidic conditions, maintaining high stabil...
P/N: H00259-31033
Ultisil LP-AQ, 5μm, 4.0×200mm
Ultisil LP-Aq is a HPLC column designed to withstand 100%–0% aqueous environments. Featuring short-chain alkyl bonding technology, it can withstand strong acidic conditions, maintaining high stabil...
P/N: H00259-31064
Ultisil LP-AQ, 5μm, 3.9×150mm
Ultisil LP-Aq is a HPLC column designed to withstand 100%–0% aqueous environments. Featuring short-chain alkyl bonding technology, it can withstand strong acidic conditions, maintaining high stabil...
P/N: H00259-31010
Ultisil LP-AQ, 5μm, 2.1×50mm
Ultisil LP-Aq is a HPLC column designed to withstand 100%–0% aqueous environments. Featuring short-chain alkyl bonding technology, it can withstand strong acidic conditions, maintaining high stabil...
P/N: H00265-33051
Ultisil LP-C3, 5μm, 300Å, 7.8×250mm
Ultisil LP-C3 column features large isopropyl side-chain groups, which protect the siloxane bonds on the silica surface, preventing hydrolysis under low-pH conditions. Designed with an unendcapped ...
P/N: H00265-33043
Ultisil LP-C3, 5μm, 300Å, 4.6×250mm
Ultisil LP-C3 column features large isopropyl side-chain groups, which protect the siloxane bonds on the silica surface, preventing hydrolysis under low-pH conditions. Designed with an unendcapped ...
P/N: H00265-33041
Ultisil LP-C3, 5μm, 300Å, 4.6×150mm
Ultisil LP-C3 column features large isopropyl side-chain groups, which protect the siloxane bonds on the silica surface, preventing hydrolysis under low-pH conditions. Designed with an unendcapped ...
P/N: H00265-31043
Ultisil LP-C3, 5μm, 4.6×250mm
Ultisil LP-C3 column features large isopropyl side-chain groups, which protect the siloxane bonds on the silica surface, preventing hydrolysis under low-pH conditions. Designed with an unendcapped ...
P/N: H00265-31041
Ultisil LP-C3, 5μm, 4.6×150mm
Ultisil LP-C3 column features large isopropyl side-chain groups, which protect the siloxane bonds on the silica surface, preventing hydrolysis under low-pH conditions. Designed with an unendcapped ...
P/N: H00265-31023
Ultisil LP-C3, 5μm, 3.0×150mm
Ultisil LP-C3 column features large isopropyl side-chain groups, which protect the siloxane bonds on the silica surface, preventing hydrolysis under low-pH conditions. Designed with an unendcapped ...
P/N: H00265-31014
Ultisil LP-C3, 5μm, 2.1×150mm
Ultisil LP-C3 column features large isopropyl side-chain groups, which protect the siloxane bonds on the silica surface, preventing hydrolysis under low-pH conditions. Designed with an unendcapped ...
P/N: H00247-31043
Ultisil LP-CN, 5μm, 4.6×250mm
Ultisil LP-CN column offers greater longevity under acidic conditions compared to the XB-CN column, and supports both normal-phase and reversed-phase modes. In reversed-phase mode, it provides uniq...
P/N: H00247-31042
Ultisil LP-CN, 5μm, 4.6×200mm
Ultisil LP-CN column offers greater longevity under acidic conditions compared to the XB-CN column, and supports both normal-phase and reversed-phase modes. In reversed-phase mode, it provides uniq...
P/N: H00247-31041
Ultisil LP-CN, 5μm, 4.6×150mm
Ultisil LP-CN column offers greater longevity under acidic conditions compared to the XB-CN column, and supports both normal-phase and reversed-phase modes. In reversed-phase mode, it provides uniq...
P/N: H00247-31039
Ultisil LP-CN, 5μm, 4.6×100mm
Ultisil LP-CN column offers greater longevity under acidic conditions compared to the XB-CN column, and supports both normal-phase and reversed-phase modes. In reversed-phase mode, it provides uniq...
P/N: H02625-22108
Ultisil LP-C8, 5μm, 30×250mm, 300Å
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...
P/N: H02625-22107
Ultisil LP-C8, 5μm, 30×150mm, 300Å
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...
P/N: H02625-22105
Ultisil LP-C8, 5μm, 21.2×150mm, 300Å
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...
P/N: H02625-22106
Ultisil LP-C8, 5μm, 21.2×250mm, 300Å
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...
P/N: H02625-22104
Ultisil LP-C8, 5μm, 21.2×50mm, 300Å
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...
P/N: H02625-22102
Ultisil LP-C8, 5μm, 10×250mm, 300Å
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...
P/N: H02625-22101
Ultisil LP-C8, 5μm, 10×150mm, 300Å
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...
P/N: H02625-22100
Ultisil LP-C8, 5μm, 10×100mm, 300Å
Welch preparative column uses the same packing materials as does analytical column, to ensure the best reproducibility of analysis and preparative scale. Special packing technique and stainless mod...
Column Specifications
C18 Columns
Series | Column | pH Range | Max Temperature | Max Pressure Tolerance |
Ultisil Series | Ultisil LP-C18 | 0.5-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
Ultisil LP-Aq | 1.0-8.0 | |||
Ultisil XB-C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
Ultisil AQ-C18 | 2.0-8.0 | |||
Ultisil Plus C18 | 2.0-8.0 | |||
Ultisil Alk C18 | 2.0-8.0 | |||
Ultisil PAH | 2.0-8.0 | |||
Ultisil Polar RP | 2.0-8.0 | |||
Ultisil ODS-3 | 2.0-8.0 | |||
Ultisil XS-C18 | 2.0-8.0 | |||
Ultisil Plus LP-C18 | 0.5-8.0 | |||
Xtimate Series | Xtimate C18 | 1.0-12.5 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
Xtimate Polar RP | 1.0-12.5 | |||
Blossmate Series | Blossmate C18 | 2.0-8.0 | 60 °C | 40 MPa |
Blossmate Aqs C18 | 2.0-8.0 | |||
Blossmate ST-C18 | 1.0-11.0 | |||
Topsil Series | Topsil C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa |
Welchrom Series | Welchrom C18 | 2.0-8.0 | 60 °C | 40 MPa |
Welchrom Vantage C18 | 2.0-8.0 | 60 °C | 40 MPa | |
Boltimate Series | Boltimate C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
60 MPa |
Boltimate EXT-C18 | 1.5-12.0 | |||
Boltimate LP-C18 | 1.0-8.0 |
C8, C4, C3, C1 and Phenyl Columns
Series | Column | pH Range | Max Temperature | Max Pressure Tolerance |
Ultisil Series | Ultisil XB-C8 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
Ultisil LP-C8 | 1.0-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
Ultisil F-C8 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
Ultisil Plus-C8 | 2.0-8.0 | |||
Ultisil XB-Phenyl | 2.0-8.0 | |||
Ultisil Phenyl-Ether | 2.0-8.0 | |||
Ultisil PFP | 2.0-8.0 | |||
Ultisil Plus-phenyl | 2.0-8.0 | |||
Ultisil XB-C4 | 2.0-8.0 | |||
Ultisil LP-C3 | 1.0-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
Ultisil XB-C30 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
Ultisil XB-C1 | 2.0-8.0 | |||
Ultisil XB-CN | 2.0-8.0 | |||
Ultisil LP-CN | 1.0-8.0 | |||
Xtimate Series | Xtimate C8 | 1.0-12.5 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
Xtimate Phenyl-Hexyl | 1.0-12.5 | |||
Xtimate C4 | 1.0-12.5 | |||
Blossmate Series | Blossmate C4 | 2.0-8.0 | 60 °C | 40 MPa |
Blossmate Phenyl | 2.0-8.0 | |||
Topsil Series | Topsil C8 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa |
Topsil phenyl-Hexyl | 2.0-8.0 | |||
Topsil CN | 2.0-8.0 | |||
Welchrom Series | Welchrom C8 | 2.0-8.0 | 60 °C | 40 MPa |
Boltimate Series | Boltimate C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
60 MPa |
Boltimate Phenyl-Hexyl | 2.0-8.0 | |||
Boltimate EXT-C18 | 1.5-12 | |||
Boltimate EXT-PFP | 1.5-10 | |||
Boltimate HILIC | 2.0-8.0 | |||
Boltimate LP-C18 | 1.0-8.0 | |||
Boltimate C8 | 2.0-8.0 | |||
Boltimate Phenyl | 2.0-8.0 |
Normal-Phase Columns
Series | Column | pH Range | Max Temperature | Max Pressure Tolerance |
Ultisil Series | Ultisil SiO2 | 2.0-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
Ultisil Diol | 2.0-8.0 | |||
Ultisil XB-NH2 | 2.0-8.0 | |||
Ultisil XB-CN | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
Topsil Series | Topsil Silica | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa |
Topsil NH2 | 2.0-8.0 |
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device