Normal/Reversed Phase Columns
P/N: H00207-31941
Ultisil DLC AQ-C18, 5µm, 4.6×150mm (1pcs/pk)
The diamond coating technology enhances the inner surface of the chromatography column with strong hydrophobicity, which overcomes the adverse effects of the column wall on separation.The high hard...
P/N: 00107-23041
Xtimate C4, 5µm, 4.6×150mm, 300Å (1pcs/pk)
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00107-23043
Xtimate C4, 5µm, 4.6×250mm, 300Å (1pcs/pk)
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00107-13043
Xtimate C4, 3µm, 4.6×250mm, 300Å (1pcs/pk)
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: 00107-13041
Xtimate C4, 3µm, 4.6×150mm, 300Å (1pcs/pk)
The Xtimate series columns are specifically designed for liquid chromatography methods, offering the flexibility to use a wide range of mobile phase systems and a broad temperature spectrum across ...
P/N: H00201-11810
Ultisil DLC UHPLC XB-C18, 1.8µm, 2.1×50mm, W-port (1pcs/pk)
The diamond coating technology enhances the inner surface of the chromatography column with strong hydrophobicity, which overcomes the adverse effects of the column wall on separation.The high hard...
P/N: H00260-31943
Ultisil DLC Plus C18, 5µm, 4.6×250mm (1pcs/pk)
The diamond coating technology enhances the inner surface of the chromatography column with strong hydrophobicity, which overcomes the adverse effects of the column wall on separation.The high hard...
P/N: H00215-31943
Ultisil DLC Polar RP, 5µm, 4.6×250mm (1pcs/pk)
The diamond coating technology enhances the inner surface of the chromatography column with strong hydrophobicity, which overcomes the adverse effects of the column wall on separation.The high hard...
P/N: H00206-31931
Ultisil DLC Diol, 5µm, 4.0×125mm (1pcs/pk)
The diamond coating technology enhances the inner surface of the chromatography column with strong hydrophobicity, which overcomes the adverse effects of the column wall on separation.The high hard...
P/N: H00201-31937
Ultisil DLC XB-C18, 5µm, 4.6×50mm (1pcs/pk)
The diamond coating technology enhances the inner surface of the chromatography column with strong hydrophobicity, which overcomes the adverse effects of the column wall on separation.The high hard...
P/N: H00207-31943
Ultisil DLC AQ-C18, 5µm, 4.6×250mm (1pcs/pk)
The diamond coating technology enhances the inner surface of the chromatography column with strong hydrophobicity, which overcomes the adverse effects of the column wall on separation.The high hard...
P/N: H00253-31943
Ultisil DLC Alk C18, 5µm, 4.6×250mm (1pcs/pk)
The diamond coating technology enhances the inner surface of the chromatography column with strong hydrophobicity, which overcomes the adverse effects of the column wall on separation. The high har...
P/N: 00101-21541
Xtimate DLC C18, 5µm, 4.6×150mm (1pcs/pk)
The diamond coating technology enhances the inner surface of the chromatography column with strong hydrophobicity, which overcomes the adverse effects of the column wall on separation.The high hard...
P/N: 00101-21543
Xtimate DLC C18, 5µm, 4.6×250mm (1pcs/pk)
The diamond coating technology enhances the inner surface of the chromatography column with strong hydrophobicity, which overcomes the adverse effects of the column wall on separation.The high hard...
P/N: H00208-31943
Ultisil DLC LP-C18, 5µm, 4.6×250mm (1pcs/pk)
The diamond coating technology enhances the inner surface of the chromatography column with strong hydrophobicity, which overcomes the adverse effects of the column wall on separation.The high hard...
P/N: 00604-21043
Blossmate Polar-Propylamide, 5µm, 4.6×250mm (1pcs/pk)
Blossmate Polar-Propylamide column provides separation forces akin to a HILIC-NH2 phase but with distinct selectivity. It exhibits low bleed in ELSD and MS detection and offers a longer operational...
P/N: 00604-21041
Blossmate Polar-Propylamide, 5µm, 4.6×150mm (1pcs/pk)
Blossmate Polar-Propylamide column provides separation forces akin to a HILIC-NH2 phase but with distinct selectivity. It exhibits low bleed in ELSD and MS detection and offers a longer operational...
P/N: H00243-31023
Ultisil MM NH2/CN, 5µm, 3.0×150mm (1pcs/pk)
Ultisil MM NH2/CN column features a mixed-mode stationary phase with amino (NH2) and cyano (CN) bonding, providing unique selectivity compared to conventional amino columns. It is particularly suit...
P/N: H00243-31041
Ultisil MM NH2/CN, 5µm, 4.6×150mm (1pcs/pk)
Ultisil MM NH2/CN column features a mixed-mode stationary phase with amino (NH2) and cyano (CN) bonding, providing unique selectivity compared to conventional amino columns. It is particularly suit...
P/N: H00243-31043
Ultisil MM NH2/CN, 5µm, 4.6×250mm (1pcs/pk)
Ultisil MM NH2/CN column features a mixed-mode stationary phase with amino (NH2) and cyano (CN) bonding, providing unique selectivity compared to conventional amino columns. It is particularly suit...
P/N: K310-02043-3P
Welchrom C18, 5µm, 4.6×250mm, Multi-batch Bundle (3pcs/pk)
Welchrom C18 column is an economical option from Welch Materials. With its low column pressure, affordable pricing, and high cost-performance ratio, it outperforms other products in the same price ...
P/N: HK275-31043-3P
Ultisil ODS-3, 5µm, 4.6×250mm, Multi-batch Bundle (3pcs/pk)
Ultisil ODS-3 column is a universal C18 column compatible with 100% aqueous phases. It has minimal adsorption for both acidic and basic compounds, ensuring excellent peak shapes. Ideal for the sepa...
P/N: HK260-31043-3P
Ultisil Plus C18, 5µm, 4.6×250mm, Multi-batch Bundle (3pcs/pk)
Ultisil Plus series features exceptional anti-fouling capability, ensuring outstanding longevity while analyzing complex matrix samples.Ultisil Plus C18 column has a lower specific surface area, sl...
P/N: HK215-31043-3P
Ultisil Polar RP, 5µm, 4.6×250mm, Multi-batch Bundle (3pcs/pk)
Ultisil Polar RP is a reversed-phase column with selectivity distinct from conventional C18. It incorporates embedded polar groups, allowing the alkyl phase to remain solvated even in highly aqueou...
Column Specifications
C18 Columns
| Series | Column | pH Range | Max Temperature | Max Pressure Tolerance |
| Ultisil Series | Ultisil LP-C18 | 0.5-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
| Ultisil LP-Aq | 1.0-8.0 | |||
| Ultisil XB-C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
| Ultisil AQ-C18 | 2.0-8.0 | |||
| Ultisil Plus C18 | 2.0-8.0 | |||
| Ultisil Alk C18 | 2.0-8.0 | |||
| Ultisil PAH | 2.0-8.0 | |||
| Ultisil Polar RP | 2.0-8.0 | |||
| Ultisil ODS-3 | 2.0-8.0 | |||
| Ultisil XS-C18 | 2.0-8.0 | |||
| Ultisil Plus LP-C18 | 0.5-8.0 | |||
| Xtimate Series | Xtimate C18 | 1.0-12.5 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
| Xtimate Polar RP | 1.0-12.5 | |||
| Blossmate Series | Blossmate C18 | 2.0-8.0 | 60 °C | 40 MPa |
| Blossmate Aqs C18 | 2.0-8.0 | |||
| Blossmate ST-C18 | 1.0-11.0 | |||
| Topsil Series | Topsil C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa |
| Welchrom Series | Welchrom C18 | 2.0-8.0 | 60 °C | 40 MPa |
| Welchrom Vantage C18 | 2.0-8.0 | 60 °C | 40 MPa | |
| Boltimate Series | Boltimate C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
60 MPa |
| Boltimate EXT-C18 | 1.5-12.0 | |||
| Boltimate LP-C18 | 1.0-8.0 |
C8, C4, C3, C1 and Phenyl Columns
| Series | Column | pH Range | Max Temperature | Max Pressure Tolerance |
| Ultisil Series | Ultisil XB-C8 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
| Ultisil LP-C8 | 1.0-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
| Ultisil F-C8 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
| Ultisil Plus-C8 | 2.0-8.0 | |||
| Ultisil XB-Phenyl | 2.0-8.0 | |||
| Ultisil Phenyl-Ether | 2.0-8.0 | |||
| Ultisil PFP | 2.0-8.0 | |||
| Ultisil Plus-phenyl | 2.0-8.0 | |||
| Ultisil XB-C4 | 2.0-8.0 | |||
| Ultisil LP-C3 | 1.0-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
| Ultisil XB-C30 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
| Ultisil XB-C1 | 2.0-8.0 | |||
| Ultisil XB-CN | 2.0-8.0 | |||
| Ultisil LP-CN | 1.0-8.0 | |||
| Xtimate Series | Xtimate C8 | 1.0-12.5 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
| Xtimate Phenyl-Hexyl | 1.0-12.5 | |||
| Xtimate C4 | 1.0-12.5 | |||
| Blossmate Series | Blossmate C4 | 2.0-8.0 | 60 °C | 40 MPa |
| Blossmate Phenyl | 2.0-8.0 | |||
| Topsil Series | Topsil C8 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa |
| Topsil phenyl-Hexyl | 2.0-8.0 | |||
| Topsil CN | 2.0-8.0 | |||
| Welchrom Series | Welchrom C8 | 2.0-8.0 | 60 °C | 40 MPa |
| Boltimate Series | Boltimate C18 | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
60 MPa |
| Boltimate Phenyl-Hexyl | 2.0-8.0 | |||
| Boltimate EXT-C18 | 1.5-12 | |||
| Boltimate EXT-PFP | 1.5-10 | |||
| Boltimate HILIC | 2.0-8.0 | |||
| Boltimate LP-C18 | 1.0-8.0 | |||
| Boltimate C8 | 2.0-8.0 | |||
| Boltimate Phenyl | 2.0-8.0 |
Normal-Phase Columns
| Series | Column | pH Range | Max Temperature | Max Pressure Tolerance |
| Ultisil Series | Ultisil SiO2 | 2.0-8.0 |
70 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa (≥5 μm) 60 MPa (<5 μm) |
| Ultisil Diol | 2.0-8.0 | |||
| Ultisil XB-NH2 | 2.0-8.0 | |||
| Ultisil XB-CN | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
||
| Topsil Series | Topsil Silica | 2.0-8.0 |
60 °C (mobile phase pH ≤6.5), 40 °C (mobile phase pH >6.5) |
40 MPa |
| Topsil NH2 | 2.0-8.0 |
Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device