Normal/Reversed Phase Columns

Normal/Reversed Phase Columns

P/N: H00207-11210
Regular price $560.00 USD
Sale price $560.00 USD
Regular price
Unit price
per 
Ultisil UHPLC columns offer high efficiency and excellent batch-to-batch reproducibility, ensuring superior chromatographic data quality while reducing the need for repeated sample analysis and min...
P/N: H00207-11014
Regular price $790.00 USD
Sale price $790.00 USD
Regular price
Unit price
per 
Ultisil UHPLC columns offer high efficiency and excellent batch-to-batch reproducibility, ensuring superior chromatographic data quality while reducing the need for repeated sample analysis and min...
P/N: H00207-11012
Regular price $660.00 USD
Sale price $660.00 USD
Regular price
Unit price
per 
Ultisil UHPLC columns offer high efficiency and excellent batch-to-batch reproducibility, ensuring superior chromatographic data quality while reducing the need for repeated sample analysis and min...
P/N: H00207-11011
Regular price $660.00 USD
Sale price $660.00 USD
Regular price
Unit price
per 
Ultisil UHPLC columns offer high efficiency and excellent batch-to-batch reproducibility, ensuring superior chromatographic data quality while reducing the need for repeated sample analysis and min...
P/N: H00207-11010
Regular price $560.00 USD
Sale price $560.00 USD
Regular price
Unit price
per 
Ultisil UHPLC columns offer high efficiency and excellent batch-to-batch reproducibility, ensuring superior chromatographic data quality while reducing the need for repeated sample analysis and min...
P/N: H00207-11009
Regular price $520.00 USD
Sale price $520.00 USD
Regular price
Unit price
per 
Ultisil UHPLC columns offer high efficiency and excellent batch-to-batch reproducibility, ensuring superior chromatographic data quality while reducing the need for repeated sample analysis and min...
P/N: H00202-41044
Regular price $430.00 USD
Sale price $430.00 USD
Regular price
Unit price
per 
Ultisil XB-C8 column features ultrapure silica matrix and is processed with high surface coverage and complete double-endcapping technology. It provides excellent peak shapes for acidic, basic, and...
P/N: H00202-41043
Regular price $410.00 USD
Sale price $410.00 USD
Regular price
Unit price
per 
Ultisil XB-C8 column features ultrapure silica matrix and is processed with high surface coverage and complete double-endcapping technology. It provides excellent peak shapes for acidic, basic, and...
P/N: H00202-41042
Regular price $400.00 USD
Sale price $400.00 USD
Regular price
Unit price
per 
Ultisil XB-C8 column features ultrapure silica matrix and is processed with high surface coverage and complete double-endcapping technology. It provides excellent peak shapes for acidic, basic, and...
P/N: H00202-41041
Regular price $400.00 USD
Sale price $400.00 USD
Regular price
Unit price
per 
Ultisil XB-C8 column features ultrapure silica matrix and is processed with high surface coverage and complete double-endcapping technology. It provides excellent peak shapes for acidic, basic, and...
P/N: H00202-41039
Regular price $390.00 USD
Sale price $390.00 USD
Regular price
Unit price
per 
Ultisil XB-C8 column features ultrapure silica matrix and is processed with high surface coverage and complete double-endcapping technology. It provides excellent peak shapes for acidic, basic, and...
P/N: H00202-41035
Regular price $600.00 USD
Sale price $600.00 USD
Regular price
Unit price
per 
Ultisil XB-C8 column features ultrapure silica matrix and is processed with high surface coverage and complete double-endcapping technology. It provides excellent peak shapes for acidic, basic, and...
P/N: H00202-41067
Regular price $820.00 USD
Sale price $820.00 USD
Regular price
Unit price
per 
Ultisil XB-C8 column features ultrapure silica matrix and is processed with high surface coverage and complete double-endcapping technology. It provides excellent peak shapes for acidic, basic, and...
P/N: H00202-41066
Regular price $680.00 USD
Sale price $680.00 USD
Regular price
Unit price
per 
Ultisil XB-C8 column features ultrapure silica matrix and is processed with high surface coverage and complete double-endcapping technology. It provides excellent peak shapes for acidic, basic, and...
P/N: H00202-33043
Regular price $560.00 USD
Sale price $560.00 USD
Regular price
Unit price
per 
Ultisil XB-C8 column features ultrapure silica matrix and is processed with high surface coverage and complete double-endcapping technology. It provides excellent peak shapes for acidic, basic, and...
P/N: H00202-33041 
Regular price $550.00 USD
Sale price $550.00 USD
Regular price
Unit price
per 
Ultisil XB-C8 column features ultrapure silica matrix and is processed with high surface coverage and complete double-endcapping technology. It provides excellent peak shapes for acidic, basic, and...
P/N: H00202-31051
Regular price $1,050.00 USD
Sale price $1,050.00 USD
Regular price
Unit price
per 
Ultisil XB-C8 column features ultrapure silica matrix and is processed with high surface coverage and complete double-endcapping technology. It provides excellent peak shapes for acidic, basic, and...
P/N: H00202-31050
Regular price $890.00 USD
Sale price $890.00 USD
Regular price
Unit price
per 
Ultisil XB-C8 column features ultrapure silica matrix and is processed with high surface coverage and complete double-endcapping technology. It provides excellent peak shapes for acidic, basic, and...
P/N: H00202-31049
Regular price $770.00 USD
Sale price $770.00 USD
Regular price
Unit price
per 
Ultisil XB-C8 column features ultrapure silica matrix and is processed with high surface coverage and complete double-endcapping technology. It provides excellent peak shapes for acidic, basic, and...
P/N: H00202-31046
Regular price $730.00 USD
Sale price $730.00 USD
Regular price
Unit price
per 
Ultisil XB-C8 column features ultrapure silica matrix and is processed with high surface coverage and complete double-endcapping technology. It provides excellent peak shapes for acidic, basic, and...
P/N: H00202-31045
Regular price $690.00 USD
Sale price $690.00 USD
Regular price
Unit price
per 
Ultisil XB-C8 column features ultrapure silica matrix and is processed with high surface coverage and complete double-endcapping technology. It provides excellent peak shapes for acidic, basic, and...
P/N: H00202-31054
Regular price $730.00 USD
Sale price $730.00 USD
Regular price
Unit price
per 
Ultisil XB-C8 column features ultrapure silica matrix and is processed with high surface coverage and complete double-endcapping technology. It provides excellent peak shapes for acidic, basic, and...
P/N: H00202-31053
Regular price $690.00 USD
Sale price $690.00 USD
Regular price
Unit price
per 
Ultisil XB-C8 column features ultrapure silica matrix and is processed with high surface coverage and complete double-endcapping technology. It provides excellent peak shapes for acidic, basic, and...
P/N: H00202-31044
Regular price $610.00 USD
Sale price $610.00 USD
Regular price
Unit price
per 
Ultisil XB-C8 column features ultrapure silica matrix and is processed with high surface coverage and complete double-endcapping technology. It provides excellent peak shapes for acidic, basic, and...

Column Specifications

C18 Columns

Series Column pH Range Max Temperature Max Pressure Tolerance
Ultisil Series Ultisil LP-C18 0.5-8.0 70 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
40 MPa (≥5 μm)
60 MPa (<5 μm)
Ultisil LP-Aq 1.0-8.0
Ultisil XB-C18 2.0-8.0 60 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
Ultisil AQ-C18 2.0-8.0
Ultisil Plus C18 2.0-8.0
Ultisil Alk C18 2.0-8.0
Ultisil PAH 2.0-8.0
Ultisil Polar RP 2.0-8.0
Ultisil ODS-3 2.0-8.0
Ultisil XS-C18 2.0-8.0
Ultisil Plus LP-C18 0.5-8.0
Xtimate Series Xtimate C18 1.0-12.5 70 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
40 MPa (≥5 μm)
60 MPa (<5 μm)
Xtimate Polar RP 1.0-12.5
Blossmate Series Blossmate C18 2.0-8.0 60 °C 40 MPa
Blossmate Aqs C18 2.0-8.0
Blossmate ST-C18 1.0-11.0
Topsil Series Topsil C18 2.0-8.0 60 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
40 MPa
Welchrom Series Welchrom C18 2.0-8.0 60 °C 40 MPa
Welchrom Vantage C18 2.0-8.0 60 °C 40 MPa
Boltimate Series Boltimate C18 2.0-8.0 60 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
60 MPa
Boltimate EXT-C18 1.5-12.0
Boltimate LP-C18 1.0-8.0

  C8, C4, C3, C1 and Phenyl Columns

Series Column pH Range Max Temperature Max Pressure Tolerance
Ultisil Series Ultisil XB-C8 2.0-8.0 60 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
40 MPa (≥5 μm)
60 MPa (<5 μm)
Ultisil LP-C8 1.0-8.0 70 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
Ultisil F-C8 2.0-8.0 60 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
Ultisil Plus-C8 2.0-8.0
Ultisil XB-Phenyl 2.0-8.0
Ultisil Phenyl-Ether 2.0-8.0
Ultisil PFP 2.0-8.0
Ultisil Plus-phenyl 2.0-8.0
Ultisil XB-C4 2.0-8.0
Ultisil LP-C3 1.0-8.0 70 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
Ultisil XB-C30 2.0-8.0 60 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
Ultisil XB-C1 2.0-8.0
Ultisil XB-CN 2.0-8.0
Ultisil LP-CN 1.0-8.0
Xtimate Series Xtimate C8 1.0-12.5 70 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
40 MPa (≥5 μm)
60 MPa (<5 μm)
Xtimate Phenyl-Hexyl 1.0-12.5
Xtimate C4 1.0-12.5
Blossmate Series Blossmate C4 2.0-8.0 60 °C 40 MPa
Blossmate Phenyl 2.0-8.0
Topsil Series Topsil C8 2.0-8.0 60 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
40 MPa
Topsil phenyl-Hexyl 2.0-8.0
Topsil CN 2.0-8.0
Welchrom Series Welchrom C8 2.0-8.0 60 °C 40 MPa
Boltimate Series Boltimate C18 2.0-8.0 60 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
60 MPa
Boltimate Phenyl-Hexyl 2.0-8.0
Boltimate EXT-C18 1.5-12
Boltimate EXT-PFP 1.5-10
Boltimate HILIC 2.0-8.0
Boltimate LP-C18 1.0-8.0
Boltimate C8 2.0-8.0
Boltimate Phenyl 2.0-8.0

  Normal-Phase Columns

Series Column pH Range Max Temperature Max Pressure Tolerance
Ultisil Series Ultisil SiO2 2.0-8.0 70 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
40 MPa (≥5 μm)
60 MPa (<5 μm)
Ultisil Diol 2.0-8.0
Ultisil XB-NH2 2.0-8.0
Ultisil XB-CN 2.0-8.0 60 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
Topsil Series Topsil Silica 2.0-8.0 60 °C (mobile phase pH ≤6.5),
40 °C (mobile phase pH >6.5)
40 MPa
Topsil NH2 2.0-8.0