P/N: 0002-02043

Advanchrom C18, 5μm, 4.6×250mm

Regular price $730.00 USD
Sale price $730.00 USD Regular price
Sale Sold out
Unit price
/per 
This is a pre order item. We will ship it when it comes in stock.

Advanchrom C18 is a fast, highly efficient, and exceptionally stable HPLC column introduced by Welch Materials, Inc. It features an ultra‑pure silica substrate treated with our proprietary organic–inorganic grafting technology, forming a highly robust hybrid layer on the silica surface and extending its pH stability range to 1–12.5. The column is further enhanced by our unique bonding and end‑capping processes for optimal performance.

Pairs well with

Advanchrom C18: Redefining HPLC Performance Through Innovation

Welch Advanchrom C18 is a high-performance HPLC column meticulously engineered for demanding separation and analysis workflows. Designed to deliver exceptional reliability and precision, Advanchrom C18 sets a new benchmark in chromatographic performance.

Breakthrough in Core Technology

Built upon ultra-pure hybrid silica, Advanchrom C18 enables an extended pH operating range of 1 to 12.5, far surpassing conventional industry standards. Coupled with our unique bonding and end-capping processes, the column maintains outstanding separation performance even under extreme analytical conditions.

Key Advantages of Advanchrom C18

  1. Wide pH Tolerance
    Capable of withstanding mobile phases across pH 1–12.5, this column is particularly well-suited for the separation of basic compounds in complex matrices. It offers flexibility for method development and expands application possibilities in challenging alkaline conditions.
  2. Enhanced Anti-Fouling Properties
    Advanchrom C18 significantly reduces the adsorption of non-polar compounds, minimizing impurity retention and column contamination. In scenarios that require high column efficiency, this column reduces maintenance downtime caused by column contamination, greatly improving overall lab efficiency. Ideal for high-throughput testing scenarios such as:
    • Food safety analysis (e.g., preservatives and additives)
    • Traditional Chinese medicine (e.g., crude herbs and decoction pieces)
    • Pharmaceutical QC (e.g., reaction monitoring and impurity profiling)
  3. Exceptional Batch-to-Batch Reproducibility
    Thanks to a fully standardized manufacturing process and rigorous quality control, Advanchrom C18 ensures consistency in key performance metrics—retention time, resolution, and plate number—across production batches. This consistency supports seamless method transfer and reliable large-scale testing.

Rigorously Validated Reproducibility

Chromatographic Conditions:

  • Column Specification: 4.6×150 mm, 5 µm
  • Mobile Phase: acetonitrile/water = 65/35
  • Flow Rate: 1.0 mL/min

Analytes:

  • Uracil
  • Phenol
  • 4-Nitrochlorobenzene
  • Toluene
Chromatogram of Reproducibility Test
Batch # Ret. Time Plates Tailing Resolution
1 4.574 11346 1.09 4.47
2 4.612 11397 1.10 4.43
3 4.603 10921 1.07 4.39
4 4.589 11320 1.08 4.40
5 4.583 11453 1.08 4.38

Five batches of column packing material were validated to deliver consistent retention time, theoretical plates, tailing factors, and resolution, allowing analysts to proceed with confidence, knowing batch variation will not compromise their results.

Proven High-Temperature Endurance

Chromatographic Conditions:

  • Column Specification: 4.6×250 mm, 5 µm
  • Mobile Phase: acetonitrile/water = 65/35
  • Flow Rate: 1.0 mL/min
  • Column Temperature: 65 ℃

Analytes:

  • Uracil
  • Phenol
  • 4-Nitrochlorobenzene
  • Toluene
Chromatogram of Temperature Endurance Test

Subjected to 65 °C column temperature and 1,000 consecutive injections, Advanchrom C18 demonstrated excellent peak shape and maintained high theoretical plate counts. Even under prolonged high-temperature use, the column performs with remarkable stability, minimizing method interruption and reruns.

Superior High-pH Stability

Chromatographic Conditions:

  • Column Specification: 2.1×50 mm, 5 µm
  • Mobile Phase: 10 mmol/L ammonium carbonate/methanol = 70/30 (pH=10.0)
  • Flow Rate: 0.21 mL/min
  • Column Temperature: 50 ℃
  • Injection Volume: 0.6 µL
  • Wavelength: 254 nm

Analytes:

  • Uracil
  • Sodium p-toluenesulfonate
  • Acetanilide
  • Procainamide

Chromatogram of Advanchrom C18 in High pH Stability Test
Advanchrom C18

Chromatogram of Conventional C18 in High pH Stability Test
Conventional C18, note the peak fronting at 60 hours

After 60 hours of continuous injection under high-pH mobile phase conditions, Advanchrom C18 continued to deliver sharp peaks and high efficiency. Its robust resistance to alkaline degradation ensures reliable long-term performance in harsh conditions.

Brand: Advanchrom

Phase: Adv-C18

Particle Size: 5μm

Pore Size: 180 Å

USP Classification: L1

Separation Mode: Reversed Mode

pH Range: 1.0-12.5

Surface Area: 220 m²/g

Carbon Load: 14%

Max.Pressure: 40MPa

Endcapped: Yes

Max.Temp.: 60°C (pH ≤6.5) and 40°C (pH >6.5)

Particle Shape: Spherical

Column Cross Reference:
(Please kindly note that columns among brands are never 100% the same. The below cross reference list indicates alternatives column(s) that will likely give a similar selectivity. Inevitable differences in retention time, resolution and theoretical plate count exist and may affect the results for certain circumstances.)

Product Description

Advanchrom C18: Redefining HPLC Performance Through Innovation

Welch Advanchrom C18 is a high-performance HPLC column meticulously engineered for demanding separation and analysis workflows. Designed to deliver exceptional reliability and precision, Advanchrom C18 sets a new benchmark in chromatographic performance.

Breakthrough in Core Technology

Built upon ultra-pure hybrid silica, Advanchrom C18 enables an extended pH operating range of 1 to 12.5, far surpassing conventional industry standards. Coupled with our unique bonding and end-capping processes, the column maintains outstanding separation performance even under extreme analytical conditions.

Key Advantages of Advanchrom C18

  1. Wide pH Tolerance
    Capable of withstanding mobile phases across pH 1–12.5, this column is particularly well-suited for the separation of basic compounds in complex matrices. It offers flexibility for method development and expands application possibilities in challenging alkaline conditions.
  2. Enhanced Anti-Fouling Properties
    Advanchrom C18 significantly reduces the adsorption of non-polar compounds, minimizing impurity retention and column contamination. In scenarios that require high column efficiency, this column reduces maintenance downtime caused by column contamination, greatly improving overall lab efficiency. Ideal for high-throughput testing scenarios such as:
    • Food safety analysis (e.g., preservatives and additives)
    • Traditional Chinese medicine (e.g., crude herbs and decoction pieces)
    • Pharmaceutical QC (e.g., reaction monitoring and impurity profiling)
  3. Exceptional Batch-to-Batch Reproducibility
    Thanks to a fully standardized manufacturing process and rigorous quality control, Advanchrom C18 ensures consistency in key performance metrics—retention time, resolution, and plate number—across production batches. This consistency supports seamless method transfer and reliable large-scale testing.

Rigorously Validated Reproducibility

Chromatographic Conditions:

  • Column Specification: 4.6×150 mm, 5 µm
  • Mobile Phase: acetonitrile/water = 65/35
  • Flow Rate: 1.0 mL/min

Analytes:

  • Uracil
  • Phenol
  • 4-Nitrochlorobenzene
  • Toluene
Chromatogram of Reproducibility Test
Batch # Ret. Time Plates Tailing Resolution
1 4.574 11346 1.09 4.47
2 4.612 11397 1.10 4.43
3 4.603 10921 1.07 4.39
4 4.589 11320 1.08 4.40
5 4.583 11453 1.08 4.38

Five batches of column packing material were validated to deliver consistent retention time, theoretical plates, tailing factors, and resolution, allowing analysts to proceed with confidence, knowing batch variation will not compromise their results.

Proven High-Temperature Endurance

Chromatographic Conditions:

  • Column Specification: 4.6×250 mm, 5 µm
  • Mobile Phase: acetonitrile/water = 65/35
  • Flow Rate: 1.0 mL/min
  • Column Temperature: 65 ℃

Analytes:

  • Uracil
  • Phenol
  • 4-Nitrochlorobenzene
  • Toluene
Chromatogram of Temperature Endurance Test

Subjected to 65 °C column temperature and 1,000 consecutive injections, Advanchrom C18 demonstrated excellent peak shape and maintained high theoretical plate counts. Even under prolonged high-temperature use, the column performs with remarkable stability, minimizing method interruption and reruns.

Superior High-pH Stability

Chromatographic Conditions:

  • Column Specification: 2.1×50 mm, 5 µm
  • Mobile Phase: 10 mmol/L ammonium carbonate/methanol = 70/30 (pH=10.0)
  • Flow Rate: 0.21 mL/min
  • Column Temperature: 50 ℃
  • Injection Volume: 0.6 µL
  • Wavelength: 254 nm

Analytes:

  • Uracil
  • Sodium p-toluenesulfonate
  • Acetanilide
  • Procainamide

Chromatogram of Advanchrom C18 in High pH Stability Test
Advanchrom C18

Chromatogram of Conventional C18 in High pH Stability Test
Conventional C18, note the peak fronting at 60 hours

After 60 hours of continuous injection under high-pH mobile phase conditions, Advanchrom C18 continued to deliver sharp peaks and high efficiency. Its robust resistance to alkaline degradation ensures reliable long-term performance in harsh conditions.

Specifications

Brand: Advanchrom

Phase: Adv-C18

Particle Size: 5μm

Pore Size: 180 Å

USP Classification: L1

Separation Mode: Reversed Mode

pH Range: 1.0-12.5

Surface Area: 220 m²/g

Carbon Load: 14%

Max.Pressure: 40MPa

Endcapped: Yes

Max.Temp.: 60°C (pH ≤6.5) and 40°C (pH >6.5)

Particle Shape: Spherical

Column Cross Reference:
(Please kindly note that columns among brands are never 100% the same. The below cross reference list indicates alternatives column(s) that will likely give a similar selectivity. Inevitable differences in retention time, resolution and theoretical plate count exist and may affect the results for certain circumstances.)

Documents