Advanchrom SCX is a high-performance strong cation exchange chromatography column designed for protein separation. It is built on advanced monodisperse nonporous polymer microspheres and utilizes a proprietary surface bonding technology. This column is ideal for the separation and characterization of charge variants in monoclonal antibodies, bispecific antibodies, fusion proteins, and antibody–drug conjugates (ADCs).

Quantity: 1 pcs/pk

Хорошо сочетается с

Advanchrom SCX is a high-performance column designed for protein separation. It is built on advanced monodisperse nonporous polymer microspheres and utilizes a proprietary surface bonding technology. This column is ideal for the separation and characterization of charge variants in monoclonal antibodies, bispecific antibodies, fusion proteins, and antibody–drug conjugates (ADCs).

Features:

  • High resolution and outstanding selectivity for charge variants of antibody molecules
  • Advanced polymer bead technology, yielding high eciency and excellent batch-to-batch consistency
  • Proprietary surface modification, oering minimized non-specific adsorption and high recovery rates

Application Examples

Analysis of NIST mAb Charge Variant

  • Column: Advanchrom SCX (4.6×150 mm, 5 μm)
  • Mobile Phase: A) 20 mM MES (pH 6.5); B) 20 mM MES (pH 6.5) + 0.5 M NaCl
  • Flow Rate: 0.3 mL/min
  • Detector Wavelength: 280 nm
  • Column Temperature: 30 °C
  • Injection Volume: 2 μL
  • Sample Concentration: 10 mg/mL
  • Gradient:
    t (min) A% B%
    0 90 10
    3 70 30
Chromatogram of NIST mAb

Analysis of Rituximab Charge Variant

  • Column: Advanchrom SCX (4.6×150 mm, 5 μm)
  • Mobile Phase: A) 20 mM MES (pH 6.5); B) 20 mM MES (pH 6.5) + 0.3 M NaCl
  • Flow Rate: 0.5 mL/min
  • Detector Wavelength: 280 nm
  • Column Temperature: 30 °C
  • Injection Volume: 10 μL
  • Sample Concentration: 1 mg/mL
  • Gradient:
    t (min) A% B%
    0 80 20
    20 65 35
    20.1 0 100
    23 0 100
    23.1 80 20
    30 80 20
Chromatogram of Rituximab

Бренд: Advanchrom

Фаза: Adv-SCX

Размер частиц: 5µm

Размер пор:

Классификация USP: L9

Режим разделения: Ion Exchange

Диапазон pH: 2.0-12.0

Площадь поверхности:

Углеродная нагрузка:

Макс.давление: 6000psi

Endcapped:

Макс.Темп.: 60℃

Форма частицы: Non-porous

Описание продукта

Advanchrom SCX is a high-performance column designed for protein separation. It is built on advanced monodisperse nonporous polymer microspheres and utilizes a proprietary surface bonding technology. This column is ideal for the separation and characterization of charge variants in monoclonal antibodies, bispecific antibodies, fusion proteins, and antibody–drug conjugates (ADCs).

Features:

  • High resolution and outstanding selectivity for charge variants of antibody molecules
  • Advanced polymer bead technology, yielding high eciency and excellent batch-to-batch consistency
  • Proprietary surface modification, oering minimized non-specific adsorption and high recovery rates

Application Examples

Analysis of NIST mAb Charge Variant

  • Column: Advanchrom SCX (4.6×150 mm, 5 μm)
  • Mobile Phase: A) 20 mM MES (pH 6.5); B) 20 mM MES (pH 6.5) + 0.5 M NaCl
  • Flow Rate: 0.3 mL/min
  • Detector Wavelength: 280 nm
  • Column Temperature: 30 °C
  • Injection Volume: 2 μL
  • Sample Concentration: 10 mg/mL
  • Gradient:
    t (min) A% B%
    0 90 10
    3 70 30
Chromatogram of NIST mAb

Analysis of Rituximab Charge Variant

  • Column: Advanchrom SCX (4.6×150 mm, 5 μm)
  • Mobile Phase: A) 20 mM MES (pH 6.5); B) 20 mM MES (pH 6.5) + 0.3 M NaCl
  • Flow Rate: 0.5 mL/min
  • Detector Wavelength: 280 nm
  • Column Temperature: 30 °C
  • Injection Volume: 10 μL
  • Sample Concentration: 1 mg/mL
  • Gradient:
    t (min) A% B%
    0 80 20
    20 65 35
    20.1 0 100
    23 0 100
    23.1 80 20
    30 80 20
Chromatogram of Rituximab
Технические характеристики

Бренд: Advanchrom

Фаза: Adv-SCX

Размер частиц: 5µm

Размер пор:

Классификация USP: L9

Режим разделения: Ion Exchange

Диапазон pH: 2.0-12.0

Площадь поверхности:

Углеродная нагрузка:

Макс.давление: 6000psi

Endcapped:

Макс.Темп.: 60℃

Форма частицы: Non-porous

Документы

Purchasing outside the United States?

Looking to purchase this product for delivery outside the U.S.? Find your local distributor, or request a quotation from our team if no distributor is available in your country.