Ultisil MM NH2/CN, 5μm, 4.6×100mm

Regular price $550.00 USD
Sale price $550.00 USD Regular price
Sale Sold out
Unit price
/per 
This is a pre order item. We will ship it when it comes in stock.

Mixed Mode Phase, as a novel packing material, exhibits distinct selectivity compared to traditional single-bonded phases, featuring dual mechanisms of hydrophobic and ion exchange actions. It is considered a trend in the future development of the liquid chromatography column industry.

  • Possesses characteristics of HILIC chromatography columns.
  • NH₂ and CN mixed bonding.
  • Utilizes high-purity spherical porous silica gel as the matrix.
  • Suitable for the analysis and separation of similar sugar compounds that are challenging to separate.
Pairs well with

Ultisil Series HPLC Columns are based on ultra-pure ( purity > 99.999% ) spherical and totally porous silica, unique bonding chemistry and proprietary surface modification techniques, producing excellent peak shape, column efficiency and exceptional lot-to-lot reproducibility. Ultisil column is the best choice for method development, owing to complete bonding chemistries and stable performance.

Features

  • Ultra-pure spherical porous silica, purity > 99.999%
  • High efficiency: theoretical plate > 80000/m
  • Excellent peak symmetry: tailing factor=0.95~1.05
  • Exceptional lot-to-lot reproducibility

SEM Pictures of Ultisil Particles


Trace Amount Metal Contents Test

A useful chromatographic test of trace amount of metal contents in the column is to compare the peak symmetry of one pair of positional isomers, 4,4’-dipyridyl and 2,2’-dipyridyl, and a neutral chelating reagent, 1,2-dihydroxylnaphthalene. 4,4’-dipyridyl, which cannot form chelating complex with metal, is used as a reference. 2,2’-dipyridyl and 1,2-dihydroxylnaphthalene, which are chelating reagents, are sensitive to trace amount metal in silica. When a C18 column based on type A silica or other so-called type B silica with higher metal content is used, the peaks of 2,2’-dipyridyl and 1,2-dihydroxylnaphthalene would tail or even totally disappear.
Ultisil XB-C18 provides good peak shapes in the separation of these three compounds under pH 7.6, which indicates Ultisil silica contains hardly any metals.

Separation of Basic Compounds Antidepressant at pH 7.0

Comparison of Peak Shape between Batch to Batch

Capacity Factor(K’) of Batch to Batch Reproducibility

Brand: Ultisil

Phase: NH2/CN

Particle Size: 5μm

Pore Size: 120Å

USP Classification: L18

Separation Mode: HILIC Mode

pH Range: 2.0-8.0

Surface Area: 320m2/g

Carbon Load:

Max.Pressure: 40Mpa

Endcapped:

Max.Temp.: 60°C(pH≤6.5) and 40°C(pH>6.5)

Particle Shape: Spherical

Product Description

Ultisil Series HPLC Columns are based on ultra-pure ( purity > 99.999% ) spherical and totally porous silica, unique bonding chemistry and proprietary surface modification techniques, producing excellent peak shape, column efficiency and exceptional lot-to-lot reproducibility. Ultisil column is the best choice for method development, owing to complete bonding chemistries and stable performance.

Features

  • Ultra-pure spherical porous silica, purity > 99.999%
  • High efficiency: theoretical plate > 80000/m
  • Excellent peak symmetry: tailing factor=0.95~1.05
  • Exceptional lot-to-lot reproducibility

SEM Pictures of Ultisil Particles


Trace Amount Metal Contents Test

A useful chromatographic test of trace amount of metal contents in the column is to compare the peak symmetry of one pair of positional isomers, 4,4’-dipyridyl and 2,2’-dipyridyl, and a neutral chelating reagent, 1,2-dihydroxylnaphthalene. 4,4’-dipyridyl, which cannot form chelating complex with metal, is used as a reference. 2,2’-dipyridyl and 1,2-dihydroxylnaphthalene, which are chelating reagents, are sensitive to trace amount metal in silica. When a C18 column based on type A silica or other so-called type B silica with higher metal content is used, the peaks of 2,2’-dipyridyl and 1,2-dihydroxylnaphthalene would tail or even totally disappear.
Ultisil XB-C18 provides good peak shapes in the separation of these three compounds under pH 7.6, which indicates Ultisil silica contains hardly any metals.

Separation of Basic Compounds Antidepressant at pH 7.0

Comparison of Peak Shape between Batch to Batch

Capacity Factor(K’) of Batch to Batch Reproducibility

Specifications

Brand: Ultisil

Phase: NH2/CN

Particle Size: 5μm

Pore Size: 120Å

USP Classification: L18

Separation Mode: HILIC Mode

pH Range: 2.0-8.0

Surface Area: 320m2/g

Carbon Load:

Max.Pressure: 40Mpa

Endcapped:

Max.Temp.: 60°C(pH≤6.5) and 40°C(pH>6.5)

Particle Shape: Spherical